Abstract :growing population and escalating construction techniques to promote the development of high-rise buildings. The proportion of high-rise buildings in major cities in the expanding, but how to do high-rise building water supply and drainage construction work has also become a topic of common concern and discussion. In view of this, the author in the text, mainly for China's current high-rise building water supply and drainage construction appears briefly describe some of the issues, and focus on the relevant drainage construction in a timely manner, I hope to be able to promote China's major cities for the development of high-rise buildings some guidance and reference.
Key words: high-rise buildings; drainage construction technology; Issues
中圖分類號(hào):TU761.6文章標(biāo)識(shí)碼:A
引言
隨著我國(guó)經(jīng)濟(jì)快速發(fā)展,我國(guó)建筑業(yè)也不斷進(jìn)步。尤其是北上廣等經(jīng)濟(jì)發(fā)達(dá)的城市,高樓林立,高層建筑物數(shù)量日漸增多。因此,高層建筑興起對(duì)施工人員的施工技術(shù)都提出了越來(lái)越高的要求。給排水施工技術(shù)在高層建筑建設(shè)中發(fā)揮著重要作用。高層建筑的推廣不僅可以大大地提高土地的使用效率,而且還能夠極大地節(jié)約建設(shè)成本。所以,我國(guó)各大城市的未來(lái)發(fā)展中,高層建筑已經(jīng)成為了一種標(biāo)志性象征。加強(qiáng)對(duì)高層建筑給排水施工中的問題進(jìn)行分析和相關(guān)施工技術(shù)的研究具有積極意義。
高層建筑給排水施工中的問題分析
新技術(shù)、新工藝、新材料的應(yīng)用為高層建筑順利實(shí)施提供了良好保障。目前,雖然高層建筑的施工已經(jīng)取得了重大的成就,但是在給排水施工中依舊存在著一些問題。給排水系統(tǒng)作為高層建筑中的一個(gè)重要組成部分,對(duì)居民生活和辦公將會(huì)產(chǎn)生重大影響。尤其是部分排水管道的堵塞以及給誰(shuí)管道的滲漏會(huì)嚴(yán)重地影響人們的日常生活和工作。高層建筑給排水施工中常見的問題主要分為以下幾個(gè)方面:
1.1高層建筑給排水施工的質(zhì)量還有待于進(jìn)一步改善
高層建筑給排水管道的施工和普普通民用建筑給排水管道施工具有很大差異[1]。大多數(shù)高層建筑的設(shè)備以及系統(tǒng)安裝往往會(huì)選擇一些面積較大的地下室或者專用設(shè)備層。由于不同設(shè)備的安裝具有不同的要求,從而給高層建筑給排水管道的施工造成了極大困難。各種設(shè)備安裝不僅減少了給排水管道施工空間,而且還給高層建筑給排水管道施工增加了難度。
高層建筑給排水施工人人員的專業(yè)水平和工作態(tài)度以及施工材料等等都會(huì)影響施工質(zhì)量。施工人員如果專業(yè)技術(shù)不夠,那么在一些給排水管道的鏈接處就很容易出現(xiàn)滲漏現(xiàn)象。受經(jīng)濟(jì)利益的驅(qū)使,一些建筑施工單位在施工過(guò)程中片面地使用不符合標(biāo)準(zhǔn)的給排水管道材料,從而忽視了給排水管道施工質(zhì)量。和西方發(fā)達(dá)國(guó)家高層建筑相比,我國(guó)高層建筑發(fā)展的歷史還比較短,因此在如何提高高層建筑的設(shè)計(jì)水平和施工水平仍然是一個(gè)長(zhǎng)期的探索和嘗試過(guò)程。
1.2高層建筑給排水施工的安全性還有待于進(jìn)一步提高
高層建筑在施工過(guò)程中由于其本身建筑高度以及層數(shù)的不同,因而如何確保給排水施工的安全需要各大施工單位進(jìn)行層層把關(guān)。給排水系統(tǒng)對(duì)于高層建筑來(lái)說(shuō)具有非常重要的意義。高層建筑物中居住用戶比較多,從而增加了給排水管道的水量。如果給排水管道在施工期間缺乏對(duì)其安全性進(jìn)行有效地管理,那么就很容易形成安全隱患。
施工人員在給排水管道施工期間如果沒有按照相關(guān)的說(shuō)明和標(biāo)準(zhǔn)進(jìn)行施工,那么就會(huì)對(duì)設(shè)備系統(tǒng)造成不良影響。尤其是給排水管道在施工中極易對(duì)輸電線路造成損壞,從而導(dǎo)致安全事故的發(fā)生。因此,做好高層建筑給排水施工的安全管理工作是一項(xiàng)緊迫的任務(wù)。
高層建筑給水排水施工技術(shù)探究
2.1高層建筑給排水系統(tǒng)的組成
高層建筑給排水系統(tǒng)主要分為三個(gè)部分。其中給水系統(tǒng)主要是包括高層建筑居民的生活用水。例如居民衛(wèi)生間沐浴以及沖馬桶等等,因此這些用水必須需要一定的給水系統(tǒng)作為支撐,才能夠確保整棟樓層用戶的正常生活用水。高層建筑的層數(shù)和高度對(duì)給水系統(tǒng)的壓力有一定要求。因此,在對(duì)給水管道的鋪設(shè)以及水表的安裝方面需要進(jìn)行全方位地考慮。排水系統(tǒng)主要是針對(duì)居民生活用水的排水設(shè)計(jì)。消防供水系統(tǒng)也是高層建筑給排水系統(tǒng)中的一個(gè)有機(jī)組成部分,其在保障居民的生命安全和財(cái)產(chǎn)安全方面起著關(guān)鍵作用。
2.2高層建筑給排水施工技術(shù)探究
2.2.1高層建筑給水管道施工技術(shù)分析
給水管道的施工程序不僅包括了對(duì)相關(guān)技術(shù)的掌握,而且還包含了對(duì)安裝程序的了解等等。因此,在給水管道的鋪設(shè)和安裝過(guò)程中需要在熟悉施工環(huán)境的基礎(chǔ)上,將給水管和排水管同時(shí)放設(shè)在高層建筑物的預(yù)留管井當(dāng)中。為了能夠方便給排水管道后期的管理和維修,在施工過(guò)程中施工人員盡量保持管井的大小為550mmx500mm。
施工人員還應(yīng)該根據(jù)不同管道的材質(zhì)以及管口的半徑和空間位置大小來(lái)安排不同的鋪設(shè)方法。比如,當(dāng)給水管道鋪設(shè)在一些并不承載重量的隔墻內(nèi)時(shí),施工人員在施工期間可以將隔墻進(jìn)行開鑿,或者在建筑施工期間預(yù)留好足夠面積的管槽。此時(shí),施工人員可以直接將給水管道埋入管槽內(nèi)。同時(shí),為了盡可能地減少給水管道出現(xiàn)滲漏的現(xiàn)象以及保證整體的美觀,施工人員可以在給水管凹槽處采取一些防水處理的措施,并且可以用統(tǒng)一的顏色對(duì)給水管道的走向進(jìn)行標(biāo)記。給水管道在施工中關(guān)鍵是做好預(yù)留預(yù)埋工作,而且還需要對(duì)給水管道的開槽以及間距進(jìn)行檢測(cè),確保施工技術(shù)符合相關(guān)的技術(shù)標(biāo)準(zhǔn)。因此,給水管道的施工需要施工人員掌握不同施工技術(shù)的特點(diǎn)和優(yōu)勢(shì),在施工過(guò)程中進(jìn)行具體分析選擇科學(xué)合理的施工方法。
2.2.2高層建筑排水管道施工技術(shù)分析
排水管道的施工同樣需要高層建筑在前期施工過(guò)程中預(yù)留好官井。排水管道和給水管道鋪設(shè)的方式具有相似性。目前,我國(guó)各大城市高層建筑排水管道施工所使用的材料是UPVC管。PVC管具有質(zhì)量較輕、耐腐蝕性、耐壓強(qiáng)度高、衛(wèi)生安全、水流阻力小、使用壽命長(zhǎng)、安裝方便等優(yōu)點(diǎn)[2]。作為排水管,UPVC管主要可以采用強(qiáng)力膠進(jìn)行粘接,但是在粘接的時(shí)候必須確保強(qiáng)力膠均勻涂上,在粘接之前也必須對(duì)管道進(jìn)行清除雜物,最好在管子與管道口用紗布進(jìn)行打磨一下,而且避免有水,因?yàn)榧偃邕€有水將會(huì)影響強(qiáng)力膠的粘接效果。在粘接時(shí)還應(yīng)該考慮到當(dāng)時(shí)的氣溫,因?yàn)槲覈?guó)北方地區(qū)環(huán)境溫差較大,容易出現(xiàn)拉壞、脹壞或者插入深度的控制把握上沒有掌握好,所以,環(huán)境溫度對(duì)粘接具有影響關(guān)系。管道受溫度的變化引起了伸縮長(zhǎng)度。
此外,排水管道的鋪設(shè)需要施工人員根據(jù)不同的坡度和地漏的分布狀況等等來(lái)進(jìn)行合理地 施工[3]。例如,在對(duì)衛(wèi)生間的下水管道進(jìn)行施工時(shí),應(yīng)該要考慮到如何能夠有效地避免臭氣的外泄以及防止污水出現(xiàn)回水的現(xiàn)象。因此,在這個(gè)時(shí)候需要施工人員在觀察現(xiàn)場(chǎng)施工環(huán)境之后合理地設(shè)置存水彎,并且在施工完畢之后還要及時(shí)地對(duì)其進(jìn)行測(cè)試。
無(wú)論是給水管道的施工還是排水管道的施工,施工人員都要考慮到安裝的位置是否合適,是否會(huì)影響周圍環(huán)境的協(xié)調(diào)等等。給排水施工期間施工人員在不影響正常施工工序的基礎(chǔ)上還要盡量保持整體的美觀和整潔。為了有效地消除給排水管道施工的安全隱患,施工人員在進(jìn)行施工之前要對(duì)管道的鋪設(shè)進(jìn)行科學(xué)合理地規(guī)劃和設(shè)計(jì),并且還需要保證每一個(gè)管道接口處都要符合施工標(biāo)準(zhǔn)。
3、結(jié)束語(yǔ)
綜上所述,高層建筑給排水施工和我們的生活具有密切聯(lián)系,給排水工程質(zhì)量好壞將會(huì)直接地影響人們?nèi)粘I睢T诟邔咏ㄖo排水施工過(guò)程中,施工人員必須嚴(yán)格按照設(shè)計(jì)標(biāo)準(zhǔn)和相關(guān)規(guī)范要求進(jìn)行施工[4]。隨著施工技術(shù)的不斷進(jìn)步,高層建筑給排水施工也需要充分地發(fā)揮高新技術(shù)的優(yōu)勢(shì),熟練地掌握給排水施工技術(shù),才能夠從整體上保障施工的質(zhì)量和安全。
【參考文獻(xiàn)】
[1]武劍英.江直樹.不同壓力控制點(diǎn)對(duì)高層建筑給水系統(tǒng)的影響比較分析探討[J].中外建筑.2009
[2]劉磊;黃通;室內(nèi)給排水系統(tǒng)常見滲漏問題及其綜合防治[A];河南省土木建筑學(xué)會(huì)2010年學(xué)術(shù)大會(huì)論文集[C];2010年
摘要:就目前國(guó)內(nèi)建筑給排水施工中存在的問題進(jìn)行了探討,介紹了施工質(zhì)量的前后期控制以及施工過(guò)程中質(zhì)量控制要點(diǎn)。
關(guān)鍵詞:建筑給排水 施工要點(diǎn) 質(zhì)量控制
1 引言
本文分析了建筑給排水工程中容易出現(xiàn)的問題及其產(chǎn)生的原因。建議從各個(gè)方面采取措施,以提高建筑給排水工程的施工質(zhì)量,保證其使用的安全性和穩(wěn)定性。
2 施工前期的質(zhì)量控制
2.1做好圖紙審查
圖紙審查足技術(shù)準(zhǔn)備工作的一項(xiàng)暈要內(nèi)容,其質(zhì)量直接影響到以后:能否正常進(jìn)行。根據(jù)給排水安裝工程的特點(diǎn),豐嚶要抓好以下幾個(gè)方面:設(shè)計(jì)圖紙是否符合國(guó)家現(xiàn)行的設(shè)計(jì)規(guī)范和當(dāng)?shù)丶夹g(shù)、經(jīng)濟(jì)政策及有關(guān)規(guī)定;沒計(jì)圖紙是否滿足建設(shè)單佗的使用功能;設(shè)計(jì)是否符合施工技術(shù)裝備條件,如需要采取特殊的技術(shù)措施時(shí),在技術(shù)上有無(wú)困難,能否保證施工安全;器具安裝基礎(chǔ)、空間是否合適;核實(shí)主要給排水設(shè)備、材料的使用規(guī)格和要求;消防設(shè)施、給水泵房等的位置及管線走向在施工前應(yīng)通過(guò)當(dāng)?shù)刂鞴懿块T的審查認(rèn)可,并明確施工要求;各專業(yè)間應(yīng)協(xié)調(diào)會(huì)審,及時(shí)解決專業(yè)間的錯(cuò)、碰、漏等問題,重點(diǎn)解決好與土建專業(yè)的協(xié)調(diào),做好設(shè)備安裝基礎(chǔ)、土建預(yù)留洞和預(yù)埋管的技術(shù)交底工作。
2.2編寫可操作的施工組織設(shè)計(jì)
施工組織設(shè)計(jì)是指導(dǎo)施工的綱領(lǐng)性文件,其編制內(nèi)容主要包括6個(gè)方面:工程概況,是將建筑形式、層高、結(jié)構(gòu)做法交待清楚;編制依據(jù),必須是現(xiàn)行有效的施工合同、施工圖紙、圖冊(cè)、施工驗(yàn)收規(guī)范、檢驗(yàn)評(píng)定標(biāo)準(zhǔn)、地方法規(guī)要求、勞動(dòng)定額等;施工準(zhǔn)備,主要包括技術(shù)準(zhǔn)備、物資準(zhǔn)備、施工現(xiàn)場(chǎng)準(zhǔn)備和施工人員的準(zhǔn)備;施工技術(shù)方案,即按照相應(yīng)的施工及驗(yàn)收規(guī)范的要求,說(shuō)明所采用的管材及附件、連接及敷設(shè)方式、防腐保溫要求、工藝流程、質(zhì)量標(biāo)準(zhǔn)、允許偏差、沖洗、試壓、測(cè)試測(cè)量要求及步驟等;施工進(jìn)度計(jì)劃,即按照本專業(yè)施工所需的條件和工序搭接要求、階段性工期要求及總工期要求進(jìn)行安排,做到工序搭接合理、作業(yè)班組相對(duì)穩(wěn)定、保證工程質(zhì)量、提高生產(chǎn)效率、縮短工期,畫出施工進(jìn)度計(jì)劃表;施工技術(shù)措施,包括質(zhì)量保證措施、成品保護(hù)措施、降低成本措施、安全措施、文明施工、冬雨季施工措施等。
2.3 把好給排水設(shè)備、材料的采購(gòu)關(guān)
給排水設(shè)備材料的品種、規(guī)格很多,為確保設(shè)備材料的質(zhì)量和安全性能及降低成本,宜進(jìn)行統(tǒng)一的管理和采購(gòu)。相關(guān)采購(gòu)部門應(yīng)根據(jù)給排水施工圖沒計(jì)的型號(hào)規(guī)格,按照給排水施上的具體要求進(jìn)行采購(gòu)。。
3 施工要點(diǎn)
3.1預(yù)留預(yù)埋及套管制作安裝
預(yù)留預(yù)埋時(shí),應(yīng)有專人按設(shè)計(jì)圖紙測(cè)量管道及設(shè)備的位置、標(biāo)高尺寸,標(biāo)好孔洞的位置,將預(yù)制好的模盒、預(yù)埋件在綁扎鋼筋前按標(biāo)志固定牢靠,模盒內(nèi)塞人紙團(tuán)、木粉等物,在澆注時(shí)應(yīng)有專人看護(hù),以免發(fā)生移位。
(1)該工程室內(nèi)冷、熱水及采暖管道穿樓板、墻體、基礎(chǔ)設(shè)置套管,穿外墻、水池壁采用鋼性防水套管預(yù)埋。
(2)套管制作。套管直徑應(yīng)比管徑大兩號(hào),若管路保溫,則套管直徑=管路直徑+2×(保溫層厚度+外纏保護(hù)層厚度)。穿墻套管長(zhǎng)度應(yīng)等于墻體厚度;穿樓板套管長(zhǎng)度應(yīng)為樓板厚度加20 mm,廚衛(wèi)間加50 mm。
(3)套管安裝。安裝管路時(shí)套入套管。穿樓板時(shí)套管上端應(yīng)高出地面20 mm,廚衛(wèi)間應(yīng)高出地面50 mm,穿墻套管與墻面齊平。安裝防水套管時(shí),將加工好的防水套管在澆注混凝土前按設(shè)計(jì)部位固定好,校對(duì)合格后一次澆注,待管道安裝完畢填料塞緊、搗實(shí)。
3.2給水管道安裝
(1)室外給水引入管與排水排出管的水平凈距須≤1 m。室內(nèi)給水與排水管道平行鋪設(shè)時(shí),兩管間的水平凈距須4:0.5 m;交叉鋪設(shè)時(shí),垂直凈距須≤0.15 m,且給水管在上。
(2)給水橫管宜有0.002~0.005坡度的坡向泄水裝置。
(3)給水立管和裝有3個(gè)或3個(gè)以上配水點(diǎn)的支管始端,均應(yīng)安裝可拆裝的連接件。
(4)管道上閥門的朝向要便于使用和維修,管徑50 mm的宜采用閘閥。
(5)冷熱水管和水龍頭并行安裝時(shí),應(yīng)符合以下規(guī)定:上下平行安裝,熱水管應(yīng)在冷水管的上面;垂直安裝,熱水管應(yīng)在冷水管的左側(cè);在衛(wèi)生器具上安裝冷熱水龍頭,熱水龍頭應(yīng)安裝在左側(cè),標(biāo)識(shí)須正確。
3.3排水管道安裝
(1)排水塑料管必須按設(shè)計(jì)要求及位置裝設(shè)伸縮節(jié),如設(shè)計(jì)無(wú)要求時(shí),伸縮節(jié)間距須≯4 m。
(2)排水主干管及水平干管管道均應(yīng)進(jìn)行通球試驗(yàn),通球球徑不小于排水管道管徑的2/3,通球率必須達(dá)到100%。
(3)生活污水塑料管道的坡度必須符合設(shè)計(jì)或規(guī)范要求。
(4)在立管上應(yīng)每隔1層設(shè)置1個(gè)檢查口,但最低層和有衛(wèi)生器具的最高層必須設(shè)置檢查口,其中心高度距操作地面為1 m,允許偏差±20 mm,檢查口的朝向應(yīng)便于檢修,在暗敷立管上的檢查口應(yīng)安裝檢查門。
(5)排水通氣管不得與風(fēng)道或煙道連接,其安裝應(yīng)符合規(guī)范要求。
(6)UPVC管材采用排水膠粘接,粘接劑使用前需搖勻。管道和承插口部位必須清理干凈,承插間隙越小越好。用砂紙或鋸條把承插口打毛,承插口內(nèi)較薄地均勻刷1遍膠,插口部位外刷兩次膠,待膠干40~60 S后插入到位,同時(shí)應(yīng)注意根據(jù)氣候變化適當(dāng)增減膠干時(shí)間。粘接時(shí)嚴(yán)禁沾水。
3.4管道附件及衛(wèi)生器具的施工
(1)閥門、水表、箱式消火栓、衛(wèi)生器具及其給水配件(角閥和水龍頭等)的安裝位置、安裝方式、安裝標(biāo)高和平直度應(yīng)符合設(shè)計(jì)和規(guī)范要求。
(2)水表安裝時(shí)外殼距墻外表面的凈距為10~30 mm。水表前后直管段>300 mm時(shí),應(yīng)煨彎使超過(guò)的管段沿墻敷設(shè)。
(3)消防水龍帶與水槍和快速接頭綁扎應(yīng)緊密牢固,并應(yīng)遵守當(dāng)?shù)叵乐鞴懿块T的統(tǒng)一規(guī)定。
(4)衛(wèi)生器具給水配件的連接應(yīng)美觀,銅管彎曲均勻,橢圓度
(5)鍍鉻的配件安裝時(shí)要使用扳手,不得使用管鉗,以保持鍍鉻表面完好無(wú)損。
(6)衛(wèi)生器具鑲接過(guò)程中應(yīng)與土建裝飾施工協(xié)調(diào)配合并做好產(chǎn)品的保護(hù),衛(wèi)生器具的排水管徑和最小坡度應(yīng)符合有關(guān)規(guī)定,安裝好的器具應(yīng)保持潔凈美觀。
3.5施工后期的質(zhì)量控制
(1)工程竣工前,對(duì)管道、閥門、水表、消火栓等進(jìn)行全面清理、清潔。
(2)做好管道、閥門、水表、水泵等設(shè)施的走向、啟閉、類別等的標(biāo)識(shí)。
(3)做好管道水壓試驗(yàn)、清洗消毒等測(cè)試項(xiàng)目的報(bào)告,整理匯總所有隱蔽工程檢查的驗(yàn)收單、各種技術(shù)資料、合格證書、質(zhì)保證書、材料測(cè)試報(bào)告等資料并裝訂成冊(cè)。
(4)繪制完整的竣工圖紙,作為竣工驗(yàn)收的依據(jù)和建設(shè)單位日后的管理維修資料。
4結(jié)語(yǔ)
建筑給排水與人們的生活息息相關(guān)。因此,我們應(yīng)不斷總結(jié)設(shè)計(jì)和施工安裝過(guò)程中的經(jīng)驗(yàn)教訓(xùn),提高建筑給排水工程的施工質(zhì)量,保證其使用的安全性和穩(wěn)定性。
參考文獻(xiàn):
關(guān)鍵詞:頂管技術(shù) ; 給排水管道; 施工工藝
Abstract: The construction of drains in the city bear the increasingly important role, for a traditional lack of water supply and drainage construction methods, the pipe jacking method, based on a simple analysis of the characteristics of the pipe jacking, the pipe jacking in to the sewer construction are analyzed and discussed, reference to further promote the application of pipe jacking construction of drainage channels.Key words: pipe jacking technology; to the sewer; construction process
中圖分類號(hào):TL353+.2文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):
地下給排水管網(wǎng)是城市基礎(chǔ)設(shè)施的重要組成部分。城市污水處理系統(tǒng)、自來(lái)水系統(tǒng)、雨水系統(tǒng)等等都屬于地下給排水管網(wǎng)之內(nèi),要對(duì)上述市政設(shè)施進(jìn)行改建、新建、擴(kuò)建,需要工程技術(shù)人員熟悉管道安裝的施工工藝、施工技術(shù)。傳統(tǒng)的挖槽埋管地下管線施工技術(shù)由于對(duì)地面交通影響較大,使本來(lái)就擁擠繁忙的城市交通如同雪上加霜,同時(shí)給市民工作、生活帶來(lái)許多不便,特別在人口稠密的城市和交通擁擠的地區(qū)以及不允許開挖的地段,這些矛盾就更加突出,成為一個(gè)迫切需要解決的問題。非開挖技術(shù)將完全能解決這些難題,提供安全及經(jīng)濟(jì)的施工方法。非開挖技術(shù)是指利用少開挖或不開挖技術(shù)來(lái)進(jìn)行地下管線的鋪設(shè)或更換的工藝。頂管技術(shù)就是在這種情況下發(fā)展起來(lái)的一種非開挖技術(shù),其在國(guó)外已廣泛使用,在國(guó)內(nèi)也已逐漸普及。隨著頂管技術(shù)在市政工程的廣泛運(yùn)用,本論文主要討論在頂管作業(yè)施工過(guò)程中出現(xiàn)了一些具體的技術(shù)問題,值得施工技術(shù)人員重視,并以此和同行共享。
1 頂管施工的特點(diǎn)
頂管法又稱為非開挖管道敷設(shè)技術(shù),它具有不需要開挖面層,就能穿越地面構(gòu)筑物和地下管線及公路、鐵路、河道的特點(diǎn),相比開挖敷設(shè)技術(shù),投資和工期將大大節(jié)省。同時(shí),頂管施工技術(shù)可以降低噪音,減少粉塵,減輕對(duì)城區(qū)的交通條件和環(huán)境狀況的干擾和破壞,屬于真正的無(wú)污染、高效率的施工技術(shù)。頂管施工法由于其上述多方面的優(yōu)點(diǎn),在市政工程中尤其是在市政給排水管線工程中得到了廣泛地應(yīng)用。概括起來(lái),頂管施工技術(shù)具有幾大方面的優(yōu)點(diǎn):施工面由線縮成點(diǎn),占地面積??;地面活動(dòng)不受施工影響,對(duì)交通干擾?。辉胍艉驼饎?dòng)低,城市中施工對(duì)居民生活環(huán)境干擾小,不影響現(xiàn)有管線及構(gòu)筑物的使用;可以在很深的地下或水下敷設(shè)管道,可以安全穿越鐵路、公路、河流、建筑物,減少沿線的拆遷工作量,降低工程造價(jià),其主要缺點(diǎn)是施工技術(shù)難度較高,需要詳細(xì)的工程地質(zhì)和水文地質(zhì)勘探資料。
2 頂管技術(shù)施工應(yīng)用分析
2.1 頂進(jìn)管的選擇。頂進(jìn)管一般選用鋼筋砼管,如沒有腐蝕要求可選用鋼管。鋼筋砼管的規(guī)格設(shè)計(jì)、配筋和應(yīng)力驗(yàn)算應(yīng)遵守有關(guān)鋼筋砼的標(biāo)準(zhǔn)和技術(shù)規(guī)程,特別是有關(guān)鋼筋砼管的標(biāo)準(zhǔn)和技術(shù)規(guī)程。
2.1.1 頂進(jìn)管直徑的選擇。頂進(jìn)管的直徑選擇是首先根據(jù)工程性質(zhì)、工程需要確定內(nèi)徑,根據(jù)頂進(jìn)管所受荷載確定砼管的配筋及壁厚,進(jìn)而確定外徑。因?yàn)轫敼芄こ坦ぷ髅嫔闲枰鋫渫谕凉と?,所以一般管?nèi)徑不小于500mm。
2.1.2 頂進(jìn)管長(zhǎng)度的選擇。頂進(jìn)管的長(zhǎng)度對(duì)頂管過(guò)程的可控性和經(jīng)濟(jì)性有很大的影響。在直線推頂?shù)那闆r下使用長(zhǎng)管可以減少裝管的次數(shù),取得良好的效果,但隨著管長(zhǎng)度的增長(zhǎng),如果偏離原定的路線,使之恢復(fù)正確路線要比使用短管更加困難。建造頂壓坑時(shí)頂壓坑的長(zhǎng)度也要增大,挖坑、支護(hù)、回填、修復(fù)的費(fèi)用將相應(yīng)地增加。反之,在直線上推頂很短的管也較困難,因?yàn)槎坦鼙容^容易向周圍土層中擠入,致使整個(gè)管列呈蛇形彎曲,這便降低了管路頂進(jìn)的可控性。
一般情況下,管長(zhǎng)度須相對(duì)于管徑來(lái)衡量,當(dāng)L/D外≤1.10時(shí),為短管;當(dāng)L/D外=1.15時(shí),為標(biāo)準(zhǔn)管;當(dāng)L/D外≥2.10時(shí)為長(zhǎng)管。
2.2 頂管施工的前期準(zhǔn)備
2.2.1 現(xiàn)場(chǎng)平面布置。平面總體布置包括起重設(shè)備、自動(dòng)控制室、料具間、管片堆場(chǎng)、拌漿棚及拌漿材料堆場(chǎng)、注水系統(tǒng)、棄土坑的布置等。始發(fā)工作井內(nèi)安裝發(fā)射架、頂管機(jī)、前頂鐵、主推千斤頂、反力架等頂進(jìn)設(shè)備,工作井邊側(cè)設(shè)置下井扶梯供施工人員上下。
2.2.2 頂管機(jī)進(jìn)、出洞處以及后靠土體加固。為確保頂管機(jī)出洞的絕對(duì)安全,需對(duì)后靠土體及進(jìn)、出洞區(qū)域土體進(jìn)行高壓旋噴樁加固。為防止頂管機(jī)進(jìn)、出預(yù)留洞導(dǎo)致泥水流失,并確保在頂進(jìn)過(guò)程中壓注的觸變泥漿不流失,必須在工作井安裝洞口止水裝置。
2.3 頂管施工的工藝。頂管施工又稱為頂進(jìn)法施工,是指利用頂進(jìn)設(shè)備將預(yù)制的箱形或圓形構(gòu)造物逐漸頂入路基,以構(gòu)成立體交叉通道或涵洞的施工方法。頂管施工需先在確定的管段之間設(shè)置工作井和接收井,然后在工作井內(nèi)安裝推力設(shè)備將導(dǎo)軌上的頂管機(jī)頭推入土體,由機(jī)頭導(dǎo)向,將預(yù)制的鋼筋混凝土管向前頂進(jìn),前端土體通過(guò)工作井運(yùn)出,最后完成管道鋪設(shè)。
2.3.1 頂管井的設(shè)計(jì)。頂管井分工作井與接收井兩種,頂管井的建造結(jié)構(gòu)有很多種類,一般使用鋼筋混凝土結(jié)構(gòu)。工作井的結(jié)構(gòu)形式通常有單孔井和單排孔井。前者形狀有圓形、正方形、矩形等,后者則大多為矩形,它們的結(jié)構(gòu)受力性能由高至低依次為圓形一正方形一矩形。結(jié)構(gòu)布置時(shí),可在井內(nèi)設(shè)置內(nèi)支撐,改善結(jié)構(gòu)受力。在建造過(guò)程中,工作井按雙向頂進(jìn)設(shè)計(jì),與接收井間隔布置,間距與設(shè)計(jì)檢查井間距一致,施工完畢,在工作井和接收井的位置上按設(shè)計(jì)要求做檢查井。
2.3.2 頂管施工工序。 ①穿墻:打開穿墻悶板將工具管頂出井外,并安裝穿墻止水裝置,主要技術(shù)施工措施如下:a穿墻管內(nèi)填夯壓密實(shí)的紙筋粘土或低強(qiáng)度水泥粘土拌和土,以起到臨時(shí)性阻水擋土作用;b為確保穿墻孔外側(cè)一定范圍內(nèi)土體基本穩(wěn)定并有足夠強(qiáng)度,工作井工具管穿墻前,對(duì)穿墻管外側(cè)采取注漿固結(jié)措施;c穿墻前對(duì)可能出現(xiàn)的問題進(jìn)行分析并制定相應(yīng)處理措施;d悶板開啟后迅速推進(jìn)工具管,同時(shí)做好穿墻止水,在一工程中我們采用止水法蘭加壓板,中間安入20mm厚的天然優(yōu)質(zhì)橡膠止水板環(huán),要求具有較高的拉伸率和耐磨性,借助管道頂進(jìn)帶動(dòng)安裝好的橡膠板形成逆向止水裝置,應(yīng)防止因穿墻管外側(cè)的土體暴露時(shí)間過(guò)長(zhǎng)而產(chǎn)生擾動(dòng)流變。②頂管出洞:頂管出洞是頂管作業(yè)中一個(gè)很值得注意的問題,頂管出洞,即頂管機(jī)和第一節(jié)管子從工作井中破出洞口封門進(jìn)入土中。開始正常頂管前的過(guò)程,是頂管技術(shù)中的關(guān)鍵工序,也是容易發(fā)生事故的工序。為防止管線出現(xiàn)偏斜,應(yīng)采取工具管調(diào)零,在工具管下的井壁上加設(shè)支撐,若發(fā)現(xiàn)下跌立即用主頂油缸進(jìn)行糾偏,工具管出洞前預(yù)先設(shè)定一個(gè)初始角彌補(bǔ)下跌等措施。③注漿減阻:在頂管施工中還有一個(gè)重要的技術(shù)措施就是通過(guò)壓注觸變泥漿填充管道周圍的空隙,形成一道泥漿保護(hù)套,起到支撐地層,減少地面沉降,減少頂進(jìn)阻力的作用。在施工中,首先對(duì)頂管機(jī)頭尾部壓漿,并要與頂進(jìn)工作同步,然后在中續(xù)間和混凝土管道的適當(dāng)位置進(jìn)行跟蹤補(bǔ)漿,以補(bǔ)充在頂進(jìn)中的泥漿損失。注漿工序一般多應(yīng)用于長(zhǎng)距離頂管施工中。④頂管糾偏:糾偏是指機(jī)頭偏離設(shè)計(jì)軸線后,利用設(shè)置在后部的糾偏千斤頂組,改變機(jī)頭端面的方向,減少偏差,使管道沿設(shè)計(jì)軸線頂進(jìn)。頂進(jìn)糾偏是采用調(diào)整4臺(tái)糾偏千斤頂組的方法,進(jìn)行糾偏操作,若管道偏左則千斤頂采用左伸右縮,反之亦然。如果同時(shí)有高程和方向偏差,則應(yīng)先糾正偏差大的一邊。糾偏應(yīng)做到在頂進(jìn)中采用小角度分級(jí)逐步進(jìn)行,勤調(diào)微糾。當(dāng)頂管機(jī)頭發(fā)生旋轉(zhuǎn)時(shí),可采取在管內(nèi)的相反方向增加壓重塊或在中間站提供旋轉(zhuǎn)糾正力矩等方法糾正。
關(guān)鍵詞:市政工程;給排水管道;管道施工;質(zhì)量控制
1鋪設(shè)給排水管道的施工前的準(zhǔn)備
1.1認(rèn)真審核設(shè)計(jì)圖紙
工程施工前,首先對(duì)設(shè)計(jì)文件、施工圖紙等進(jìn)行會(huì)審、檢查核對(duì)。檢查其是否符合現(xiàn)場(chǎng)和施工的實(shí)際條件設(shè)計(jì)深度是否滿足施工要求,盡量避免因設(shè)計(jì)疏忽或考慮不周給后續(xù)施工帶來(lái)矛盾和困難,避免施工中出現(xiàn)各種管道之同、管道與電纜、橋梁,管線與粱柱沖突等現(xiàn)象。對(duì)需要預(yù)留、預(yù)埋的內(nèi)容,應(yīng)在專業(yè)圖紙上進(jìn)行查漏補(bǔ)缺,糾正錯(cuò)誤,明確施工要求等等。
1.2開工申請(qǐng)及監(jiān)理細(xì)則
根據(jù)排水管道工程特點(diǎn)、設(shè)計(jì)要求、規(guī)范規(guī)定和承包人中報(bào)的施工組織設(shè)計(jì)(包括施工工藝、施工方案、組織措施以及準(zhǔn)備工作,各類進(jìn)場(chǎng)技術(shù)人員、工種、材料和機(jī)具設(shè)備檢查結(jié)果情況及現(xiàn)場(chǎng)施工條件等因素),審批排水管道工程開工申請(qǐng),并制定工程質(zhì)量監(jiān)理工作細(xì)則等。
1.3對(duì)材料、成品的控制
認(rèn)真檢查工程所用的混凝土管、水泥、沙石等規(guī)格、性能、質(zhì)量標(biāo)準(zhǔn)是否符合設(shè)計(jì)要求,尤其是混凝土管和水泥,需要到廠家進(jìn)行實(shí)地考察和抽檢
1.4挖槽前準(zhǔn)備工作
在街道上施工,無(wú)論工程大小,挖土前應(yīng)在溝槽兩端設(shè)立安全設(shè)施,如路障及危險(xiǎn)旗之類的警告標(biāo)志,當(dāng)日不能完工的,夜晚應(yīng)懸掛紅燈,每3 0 m左右一盞,交叉路口適當(dāng)增設(shè)燈數(shù)。挖槽前還要了解該段的土質(zhì),水文及地下構(gòu)造物的位置,靠近建筑物挖槽時(shí),應(yīng)事先做好地面清障工作及制定安全防護(hù)措施;準(zhǔn)備好板、樁等支撐材料和施工排水設(shè)備。
2 給排水管道的施工過(guò)程質(zhì)量控制
2.1溝槽開挖與支護(hù)
市政工程給排水管道的施工項(xiàng)目中,土方的工作量占整個(gè)工程的很大比重,在安排上采用輪胎式挖掘機(jī)、推土機(jī)配合開挖與人工開挖相結(jié)合,在需土方運(yùn)輸?shù)牡胤脚鋫湟恍┳孕镀?。在開挖前逐一探明地下既有管道、電纜和其他構(gòu)筑物的位置,將調(diào)查結(jié)果和處理方案送交業(yè)主和相關(guān)管理單位確認(rèn),以便進(jìn)行相應(yīng)的保護(hù)、遷移等措施,保證開挖工作持續(xù)進(jìn)行。當(dāng)?shù)叵滤惠^高或雨季施工時(shí),要求采取排水措施,保證水位低于工作面2 m,防止溝槽內(nèi)長(zhǎng)時(shí)間積水,造成浮管現(xiàn)象。此外考慮到基槽暴露時(shí)間過(guò)長(zhǎng)會(huì)引起基槽變形,應(yīng)盡可能減少晾槽時(shí)間(不超過(guò)2~3h)。施工時(shí)應(yīng)掌握天氣變化,嚴(yán)禁基槽泡水;當(dāng)遇到溝槽底部為巖石基礎(chǔ)時(shí),要求增加開挖深度30cm;當(dāng)遇到軟弱基礎(chǔ)或有其它埋置物時(shí),會(huì)同有關(guān)部門研究后處理。
2.2施工測(cè)量
施工測(cè)量是一項(xiàng)技術(shù)性很強(qiáng)的工作,貫穿于排水管道施工的始終,必須設(shè)專人專項(xiàng)來(lái)完成,以確保測(cè)量的及時(shí)性和準(zhǔn)確性。為保證每道工序完成后的數(shù)據(jù)準(zhǔn)確無(wú)誤,應(yīng)在自檢自測(cè)的工序中要求允許偏差精度比規(guī)定的再提高50%,并由專業(yè)測(cè)量施工工程師進(jìn)行測(cè)量,再由另一測(cè)量工程師進(jìn)行復(fù)核。測(cè)量?jī)x器必須經(jīng)標(biāo)定后方可使用。
2.3管基制作
管溝開挖驗(yàn)收合格后,可按照?qǐng)D紙?jiān)O(shè)計(jì)尺寸、標(biāo)號(hào)及中心線等要求進(jìn)行管基的施工。管基施工時(shí),土質(zhì)基底不得裸落過(guò)久,同時(shí)考慮到保養(yǎng)、氣候、混凝土遠(yuǎn)距離運(yùn)輸?shù)炔焕蛩?,混凝土可提高一個(gè)強(qiáng)度等級(jí)或采取加早強(qiáng)劑等措施,待管基達(dá)到一定強(qiáng)度后再下管。
2.4管材安裝
2.4.1工程塑料埋地排水管道的施工技術(shù)
2.4.2塑料埋地排水管道的選材與敷設(shè)
塑料埋地排水管主要承受的是外壓的荷載,包括管頂土重荷載和地面上汽車帶來(lái)的活荷載等。根據(jù)前面的理論分析,敷設(shè)的條件和質(zhì)量對(duì)于其是否能夠安全工作起到?jīng)Q定性的作用。國(guó)內(nèi)外應(yīng)用埋地塑料排水管的實(shí)踐證明,工程成敗常常取決于敷設(shè)。
2.5溝槽回填
在《給水排水管道工程施工及驗(yàn)收規(guī)范》中,對(duì)溝槽回填土的壓實(shí)度沒有提出具體要求。所以當(dāng)施工單位問及此事時(shí),回答多種多樣,而且具體數(shù)字也相差較大。在《給水排水管道工程施工及驗(yàn)收規(guī)范》中,對(duì)回填土的壓實(shí)度就說(shuō)得比較詳細(xì),可在工程設(shè)計(jì)中直接套用?,F(xiàn)將其3 5 1 2~3517條的內(nèi)容選摘如下:
第一,管道溝槽位于路基范圍時(shí),管頂以上25cm范圍內(nèi)回填土表層的壓實(shí)度不應(yīng)小于87%,其他部位回填土的壓實(shí)度應(yīng)符合相關(guān)的規(guī)定。
第二,管道兩側(cè)回填土的壓實(shí)度應(yīng)符合下列規(guī)定:
a.對(duì)混凝土、鋼筋混凝土和鑄鐵圓形管道,其壓實(shí)度不應(yīng)小于9 0%;對(duì)鋼管道,壓實(shí)度不應(yīng)小于95%。
b.矩形或拱形管渠的壓實(shí)度應(yīng)按設(shè)計(jì)件規(guī)定執(zhí)行。設(shè)計(jì)文件無(wú)規(guī)定時(shí),其壓實(shí)度不應(yīng)小于90%。
第三,當(dāng)管道覆土較淺,管道的承載力低,壓實(shí)工具的荷載較大,或原土回填達(dá)不到要求的壓實(shí)度時(shí),可與設(shè)計(jì)單位協(xié)商采用石灰土、砂、砂礫等具有結(jié)構(gòu)強(qiáng)度或可以達(dá)到要求的其他材料回填。
第四,沒有修路計(jì)劃的溝槽回填土,在管道頂部以上高為50cm,寬為管道結(jié)構(gòu)外緣范圍內(nèi)應(yīng)松填,其壓實(shí)度不應(yīng)大于85%;其余部位,當(dāng)設(shè)計(jì)文件沒有規(guī)定時(shí),不應(yīng)小于9 o%。
第五,管道溝槽回填土,當(dāng)原土含水量高且不具備降低含水量條件不能達(dá)到要求壓實(shí)度時(shí),管道兩側(cè)及溝槽位于路基范圍內(nèi)的管道頂部以上,應(yīng)回填石灰土、砂、砂礫或其他可以達(dá)到要求壓實(shí)度的材料。
3給排水管道的施工常見問題的質(zhì)量控制
3.1管道位置偏移或積木
3.1.1產(chǎn)生原因
測(cè)量差錯(cuò),施工走樣和意外的避讓原有構(gòu)筑物,在平面上產(chǎn)生位置偏移,立面上產(chǎn)生積水甚至倒坡現(xiàn)象。
3.1.2預(yù)防措施
(1)防止測(cè)量和施工造成的病害措施主要有:一,施工前要認(rèn)真按照施工測(cè)量規(guī)范和規(guī)程進(jìn)行交接樁復(fù)測(cè)與保護(hù)。二,施工放樣要結(jié)合水文地質(zhì)條件,按照埋置深度和設(shè)計(jì)要求以及有美規(guī)定放樣,且必須進(jìn)行復(fù)測(cè)檢驗(yàn)其誤差符合要求后才能交付施工。三,施工時(shí)要嚴(yán)格按照樣樁進(jìn)行,溝槽和平基要做好軸線和縱坡測(cè)量驗(yàn)收。
(2)施工過(guò)程中如意外遇到構(gòu)筑物必須避讓時(shí),應(yīng)在適當(dāng)?shù)奈恢迷鲈O(shè)連接并,其何以直線連通,連接井轉(zhuǎn)角應(yīng)大于135°。
3.2管道滲漏水,閉水試驗(yàn)不合格
3.2.1產(chǎn)生原困
基礎(chǔ)不均勻下沉,管材及其接口施工質(zhì)量差、閉水段端頭封堵不嚴(yán)密、井體施工質(zhì)量差等原因均可產(chǎn)生漏水現(xiàn)象。
3.2.2防治措施:
管道基礎(chǔ)條件不良將導(dǎo)致管道和基礎(chǔ)出現(xiàn)不均勻沉陷,一般造成局部積水,嚴(yán)重時(shí)會(huì)出現(xiàn)管道斷裂或接口開裂。預(yù)防措施是:
一、認(rèn)真按設(shè)計(jì)要求施工,確保管道基礎(chǔ)的強(qiáng)度和穩(wěn)定性。當(dāng)?shù)鼗刭|(zhì)水文條件不良時(shí),應(yīng)進(jìn)行換良處治,提高基槽底部的承載力。
二、如果槽底土壤被擾動(dòng)或受水浸泡,應(yīng)先挖除松軟土層后和超挖部分用砂或碎石等穩(wěn)定性好的材料回填密實(shí)。
三、地下水位以下開挖土方時(shí),應(yīng)采取有救措施做好抗槽底部排水降水工作,確保干槽開挖,必要時(shí)可在槽坑底預(yù)留20cm厚土層,待后續(xù)工序施工時(shí)隨挖隨封閉。
4結(jié)束語(yǔ)
城市給排水管道系統(tǒng)是現(xiàn)代化城市不可缺少的重要城市市政基礎(chǔ)設(shè)施,也是城市水污染防治和城市排澇、防洪的骨干工程。對(duì)市政給排水管道工程施工監(jiān)理中要注意的幾個(gè)方面,僅供各位工程施工人員參考,以便能在未來(lái)的市政給排水工程施工監(jiān)理中起到一定的借鑒和參考作用。使城鎮(zhèn)給排水工程在施工中不斷的得到改進(jìn)和完善。
參考文獻(xiàn)
關(guān)鍵詞:建筑給排水,施工,技術(shù)
某公寓樓為一類高層建筑,負(fù)三層至七層為裙樓,負(fù)二、負(fù)三層為設(shè)備層,負(fù)二層設(shè)車庫(kù),負(fù)一層至四層為商場(chǎng),五層、六層為餐廳,七層為辦公室,八至三十層為塔樓住戶層,其建筑面積約為3.9萬(wàn)平方米。該項(xiàng)目給水、排水工程概況:⑴給水系統(tǒng)。供水方式為:市政給水管→地下水池→泵→水箱→各用戶的上行下給供水方式。⑵排水系統(tǒng)。論文參考。污水經(jīng)埋地式污水處理裝置處理后排入市政污水管。雨水經(jīng)集中收集后排入規(guī)劃河道。⑶管材。生活給水管采用PE管,熱容連接;屋面給水管及埋地管采用涂塑鋼管法蘭連接。消火栓系統(tǒng):DN≤100鍍心鋅鋼管,DN>100采用焊接鋼管,噴淋采用內(nèi)外熱渡鋅鋼管。論文參考。污水管采用UPVC排水管,排水出戶管采用埋地UPVC排水管。⑷管道安裝。室內(nèi)給水管沿樓板底穿梁,管道基礎(chǔ)穿樓板穿屋面等應(yīng)在土建施工時(shí)及時(shí)準(zhǔn)確的預(yù)留孔洞或預(yù)留套管,埋地出戶管管頂據(jù)基礎(chǔ)梁底不得小于150mm。排水立管和排水橫管連接應(yīng)采用45°斜三通、四通或90°斜三通。地面應(yīng)有1~2%坡度坡向地漏,地漏頂面應(yīng)低于地面5~10mm。
1.給水、排水主要施工技術(shù)與工藝
1.1 給水管安裝
1.1.1 給水管孔洞在土建進(jìn)行結(jié)構(gòu)工程施工時(shí),均應(yīng)配合土建預(yù)留孔洞,一般采用木制方盒在綁扎鋼筋的同時(shí)進(jìn)行預(yù)埋。預(yù)埋的坐標(biāo)與標(biāo)高必須準(zhǔn)確無(wú)誤,預(yù)埋完畢在澆搗砼之前應(yīng)由施工員與質(zhì)檢員進(jìn)行復(fù)核,確保無(wú)漏埋、錯(cuò)埋,澆搗砼時(shí)須由施工班組派人進(jìn)行查看。
1.1.2 工藝流程
安裝準(zhǔn)備→預(yù)制加工→干管安裝→立管安裝→支管安裝→管道試壓→管道沖洗
1.1.3 鋁塑管之間連接采用螺紋連接。
1.1.4 注射成型的專用配件與金屬配件、器具螺接時(shí),應(yīng)采用聚四氯乙烯生料帶作為密封填充物。
1.1.5 明敷設(shè)管道的支承件最大間距不得大于規(guī)范規(guī)定:
1.1.6 給水系統(tǒng)在管網(wǎng)安裝完畢,應(yīng)按規(guī)定分系統(tǒng)進(jìn)行試壓。
試驗(yàn)壓力應(yīng)為管道系統(tǒng)工作系統(tǒng)工作壓力的1.5倍,但不得小于0.6MPa,試驗(yàn)用的壓力表須不少于2塊,表的滿刻度值應(yīng)為試驗(yàn)壓力的1.5-2倍,其精度不低于1.5級(jí),壓力表是經(jīng)過(guò)鑒定合格的產(chǎn)品并附有“鑒定合格證明書“。水壓試驗(yàn)之前,對(duì)試壓管道應(yīng)采取安全有效的固定和保護(hù)措施,但接頭部位必須明露。
水壓試驗(yàn)步驟:首先,將試壓管道末端封堵,緩慢注水,同時(shí)將管道內(nèi)氣體排出;其次,充滿水后,進(jìn)行水密性檢查;三是加壓應(yīng)采用手動(dòng)試壓泵緩慢升壓,升壓時(shí)間不得小于10分鐘;四是壓力升至規(guī)定試驗(yàn)壓力后,停止加壓并應(yīng)穩(wěn)壓1小時(shí),觀察接頭部位是否有滲漏現(xiàn)象;五是穩(wěn)壓1小時(shí)后,若有壓力降,應(yīng)補(bǔ)壓至規(guī)定的試驗(yàn)壓力值,15分鐘內(nèi)壓力降不超過(guò)0.05Mpa為合格。
1.1.7 給水系統(tǒng)在施工完畢后交付使用之前,需消毒和用飲用水增壓沖洗,確保給水管道暢通,并清除滯留或掉入管道內(nèi)的灰塵、雜質(zhì)、污物,沖洗水流速宜大于2m/s,直至出口處的水濁度與進(jìn)水相當(dāng)為止。
1.2排水管道安裝(含污、廢水系統(tǒng)、雨水系統(tǒng))
1.2.1 土建主體工程基本完成,現(xiàn)澆樓板穿管孔洞已按圖紙要求及適用位置的尺寸預(yù)留好。管道通過(guò)的房間內(nèi)位置線及地面水平線已檢測(cè)完畢,室內(nèi)裝飾的種類厚度已確定,各種衛(wèi)生器具的選型已確定。
1.2.2 工藝流程
安裝準(zhǔn)備→預(yù)制加工→干管安裝→立管安裝→支管安裝→卡件固定→封口堵洞→閉水試驗(yàn)→通水試驗(yàn)
1.2.3 預(yù)制加工
根據(jù)圖紙要求并結(jié)合實(shí)際情況,按預(yù)留口位置測(cè)量尺寸,量好管道尺寸,進(jìn)行斷管,斷口要平齊,粘接前應(yīng)先試插,合格后用毛刷涂抹粘接劑,先涂承口,后涂插口,隨即用力垂直插入,插入粘接時(shí)將插口稍作轉(zhuǎn)動(dòng),以利粘接劑分布均勻,粘牢后立即將溢出的粘接劑擦拭干凈。
1.2.4 立管安裝應(yīng)按設(shè)計(jì)要求設(shè)置固定支架或支承件后,再進(jìn)行立管的安裝,安裝立管時(shí),將匯水配件、伸縮節(jié)等組裝在立管上,核對(duì)無(wú)誤后進(jìn)行粘接,安裝完畢后,隨即將立管固定。立管承口處側(cè)面的距離應(yīng)控制在20-50mm之間;
1.2.5 橫管安裝應(yīng)根據(jù)實(shí)測(cè)大樣圖將預(yù)制好的橫管先進(jìn)行組裝,用臨時(shí)吊掛,核查無(wú)誤后再進(jìn)行粘接。論文參考。粘接后,應(yīng)迅速擺正位置,按規(guī)定校正坡度,待粘接固化后,再緊固支承件,將敞口臨時(shí)封堵。
1.2.6 排水管道根據(jù)設(shè)計(jì)要求做好灌水和通水試驗(yàn),并做好保護(hù)措施防止污染。
1.3 衛(wèi)生潔具安裝
臺(tái)式洗面盆安裝:根據(jù)土建給出的室內(nèi)水平標(biāo)高線,核對(duì)排水管甩頭及給水管甩頭的管徑、坐標(biāo)與標(biāo)高,對(duì)不符合要求的修整到符合要求為止;用符合設(shè)計(jì)要求并經(jīng)外觀檢查合格、無(wú)缺損的閥門連接給水管甩頭,連接后的閥門朝向應(yīng)合理、一致,標(biāo)高準(zhǔn)確,管道應(yīng)正直,坡度正確,接口嚴(yán)密;用符合設(shè)計(jì)并經(jīng)外觀檢查合格的排水栓、存水彎管連接洗臉盆排水口與排水管甩頭,連接后管道應(yīng)正直,坡度正確,接口嚴(yán)密、牢固;面盆與臺(tái)式大理石接縫處應(yīng)上膠;洗面盆安裝完畢后應(yīng)用草袋加以覆蓋,防止表面受損和整個(gè)器具損壞。
2.常見質(zhì)量通病及防范措施
2.1 給水系統(tǒng)
(1)立管坐標(biāo)超差、不垂直。施工時(shí)應(yīng)認(rèn)真用線附找準(zhǔn)立管中心。
(2)支管各配水點(diǎn)出口高度不一。施工時(shí)使用透明細(xì)塑料管內(nèi)裝水,根據(jù)連通管原理控制配水點(diǎn)的水平度。
(3)水表外殼距墻內(nèi)表面過(guò)近。應(yīng)按規(guī)范規(guī)定的要求,對(duì)表位進(jìn)行調(diào)整或更換管段。
2.2 排水系統(tǒng)
(1)立管坐標(biāo)超差、不垂直。原因是立管位置安排不當(dāng),安裝過(guò)程中拉垂直線輔助施工。
(2)橫管坡度達(dá)不到要求,出現(xiàn)坡度過(guò)大過(guò)小,甚至倒坡。安裝前應(yīng)根據(jù)規(guī)范要求計(jì)算支管高差,放樣,準(zhǔn)確無(wú)誤后方可制作安裝。
(3)地漏安裝過(guò)高或過(guò)低,影響使用。找平地平線,確定地漏安裝高度。
(4)粘接口漏水。安裝時(shí)管道接口處粘接劑涂刷均勻,粘接處粘接劑處理干凈。
3.成品保護(hù)措施
3.1 給水管道成品保護(hù)
一是安裝好的管道不得用做支撐放腳手板,不得踏壓,其支托架不得作為其他用途的受力點(diǎn);二是管道口做臨時(shí)封堵,以防雜物丟入。三是閥門的手輪在安裝時(shí)應(yīng)卸下,交工前統(tǒng)一安裝好;四是水表應(yīng)有保護(hù)措施,為防止破壞或丟失,可統(tǒng)一在竣工前裝好。
3.2 排水管道成品保護(hù)
一是管道安裝完成后,應(yīng)將所有管口封閉嚴(yán)密,防止雜物進(jìn)入,造成管道堵塞;二是安裝完的管道加以保護(hù),尤其立管距地20mm以下,就應(yīng)用木板捆綁保護(hù);三是嚴(yán)禁利用塑料管道作為腳手架的支點(diǎn)或安全帶的拉點(diǎn),吊頂?shù)牡觞c(diǎn),不允許明火烘烤塑料管,以防管道變形;四是油漆粉刷前將管道包裹,以免被污染。
3.3 衛(wèi)生器具成品保護(hù)
一是潔具在搬運(yùn)和安裝時(shí)要防止磕碰,穩(wěn)裝后潔具排水出口應(yīng)用防護(hù)用品堵好,鍍鉻零件用紙包好,以免堵塞或損壞;二是在釉面磚墻面剔孔洞時(shí),宜用手電鉆或先用小鏨子輕剔掉釉面,待剔至底層處方可用力,但不得過(guò)猛,以免將面層剔碎或震成空鼓現(xiàn)象;三是安裝完的潔具加以保護(hù),防止?jié)嵕?、器具受損和整個(gè)潔具損壞;四是通水試驗(yàn)前應(yīng)檢查地漏是否暢通,分戶閥門是否關(guān)好,然后逐層一一進(jìn)行通水試驗(yàn),以免漏水使裝修工程受損。
總之,給排水施工是建筑工程的一個(gè)有機(jī)組成部分,其施工質(zhì)量的好壞直接影響建筑工程的質(zhì)量。及時(shí)、完整、有序地抓好給排水施工的質(zhì)量控制,是創(chuàng)建優(yōu)良工程的基礎(chǔ)。
【參考文獻(xiàn)】
[1]王漢發(fā).建筑給排水施工問題及對(duì)策探討[J].現(xiàn)代商貿(mào)工業(yè),2010,(02):283.
[2]陳永科.建筑給排水施工中的問題探討[J].建材技術(shù)與應(yīng)用,2009,(02).
關(guān)鍵詞:施工工藝、施工管理、施工圖審查、施工工序
隨著我國(guó)的建筑行業(yè)的不斷發(fā)展,城建速度加快,高層建筑不斷涌現(xiàn)。與此同時(shí)由于建筑給排水直接的關(guān)系著住戶的生活質(zhì)量。所以建筑業(yè)給排水的施工質(zhì)量管理與控制逐漸的成為建筑施工所關(guān)注的問題。為了確保建筑給排水施工的質(zhì)量有效地解決我國(guó)現(xiàn)階段出現(xiàn)的建筑給排水施工質(zhì)量問題,本文根據(jù)施工經(jīng)驗(yàn)與給排水理論著重研究了建筑給排水施工質(zhì)量管理措施與方法。力爭(zhēng)通過(guò)解決施工工藝、施工管理、施工圖審查、施工工序管理等措施來(lái)解決我國(guó)建筑給排水施工中的質(zhì)量問題,同時(shí)為今后的建筑給排水施工提供一定的參考。
現(xiàn)階段我國(guó)在建筑給排水施工中經(jīng)常出現(xiàn)的質(zhì)量問題有:(1)建筑給排水施工工藝問題。比如在設(shè)備安裝位置不正確的情況下,非常容易產(chǎn)生噪聲并且有可能導(dǎo)致水管連接處滲水等問題?;蛘邥?huì)出現(xiàn)材料控制不嚴(yán)現(xiàn)象,在使用過(guò)程中會(huì)發(fā)生水管爆裂或者水嘴不能關(guān)嚴(yán)現(xiàn)象。給排水設(shè)計(jì)中計(jì)算有誤或者考慮不周,比如會(huì)出現(xiàn)管徑選擇偏小、水泵或者其他加壓貯水設(shè)備選擇不當(dāng)?shù)痊F(xiàn)象;(2)建筑給排水施工管理問題。有些給排水施工由于管理不嚴(yán),部分給排水工程并未按照《建筑給水排水設(shè)計(jì)規(guī)范》的要求進(jìn)行。比如在部分施工過(guò)程中出現(xiàn)把應(yīng)該進(jìn)行單獨(dú)設(shè)計(jì)的室內(nèi)雨水管道接入生活污水管道。這樣會(huì)導(dǎo)致在雨季來(lái)臨時(shí)生活污水管道超出負(fù)荷不能進(jìn)行有效的排水,導(dǎo)致了污水外溢從而影響居民的正常生活;(3)建筑給排水施工圖審查問題。根據(jù)國(guó)務(wù)院所頒發(fā)的《建筑工程質(zhì)量管理?xiàng)l例》和建設(shè)部提出的《關(guān)于建筑工程施工圖設(shè)計(jì)文件審查暫行辦法》的有關(guān)規(guī)定,為了保障建筑給排水施工的質(zhì)量。要嚴(yán)格做到對(duì)于新建、改建、擴(kuò)建的建筑施工圖必須要進(jìn)行認(rèn)真審查,施工圖合格后才能進(jìn)行交付使用。如果在建筑給排水施工圖出現(xiàn)了問題,則會(huì)出現(xiàn)實(shí)際與設(shè)計(jì)安裝的情況不符或者按照設(shè)計(jì)無(wú)法正常吃用等現(xiàn)象。(4)建筑給排水施工工序問題。給排水的施工工序?qū)τ谑┕べ|(zhì)量十分重要,如果出現(xiàn)工序顛倒的情況,就常常會(huì)發(fā)生管道安裝不合理等現(xiàn)象。在此情況下,本文提出以下幾點(diǎn)措施來(lái)解決給排水施工所出現(xiàn)的質(zhì)量問題:
優(yōu)化施工工藝、嚴(yán)格管理工藝質(zhì)量
在建筑給排水施工階段,選擇一個(gè)適當(dāng)?shù)氖┕すに噷?duì)建筑給排水的施工質(zhì)量的影響非常大。對(duì)于高層建筑來(lái)說(shuō),應(yīng)當(dāng)重視預(yù)留預(yù)埋工作。由于高層建筑一般具有施工面積較大、垂直高度高,施工組織管理難度大等特點(diǎn)。在此情況下施工工藝中就要靈活的進(jìn)行分區(qū)安裝的施工方法。分區(qū)安裝施工方法的原則一般是按施工的層數(shù)劃分為三個(gè)區(qū)域或者按照安裝量的密集程度進(jìn)行區(qū)域劃分。一般情況下公共衛(wèi)生間、浴室等用水量較大并且管道按照工程量比較密集的地方進(jìn)行單獨(dú)分區(qū)。對(duì)于管道敷設(shè)中的管道嵌墻工作應(yīng)當(dāng)進(jìn)行預(yù)留凹槽工作。具體的凹槽尺寸需要達(dá)到深度20mm、寬度40~60mm。與此同時(shí)必須進(jìn)行凹槽平整工作,待到管道安裝、固定、試壓等程序檢驗(yàn)合格后,利用M7.5級(jí)水泥砂漿填補(bǔ)密實(shí)凹槽。在進(jìn)行管溝回填的施工工藝階段時(shí),要注意在管道附近100mm以內(nèi)的環(huán)境內(nèi)回填地不可以?shī)A雜尖硬物體。施工中應(yīng)盡量完成工藝所要求的先利用砂土或過(guò)篩的顆粒不大于12mm的泥土進(jìn)行管頂以上300mm處回填工作,在進(jìn)行灑水夯實(shí)工作,最后利用原土回填到管溝頂面。高層給排水施工室的埋地管道深度不能小于300mm。在熱熔連接工作進(jìn)行時(shí),由于高層的工作量比較大所以要注意在加熱時(shí),將管材的管端無(wú)旋轉(zhuǎn)的插入到加熱套內(nèi),并且盡量將管材插入至所標(biāo)識(shí)的連接深度;與此同時(shí)將管件無(wú)旋轉(zhuǎn)的推入到加熱頭上,并且也要插入至規(guī)定深度的標(biāo)識(shí)處。在此過(guò)程中要注意管材,管件,使它不受扭,彎和拉伸。二、強(qiáng)化施工管理、加強(qiáng)質(zhì)量評(píng)定管理體系
在我國(guó)現(xiàn)階段實(shí)行的建筑給排水施工準(zhǔn)則有《建筑給水排水設(shè)計(jì)規(guī)范》、《建筑安裝工程質(zhì)量檢驗(yàn)評(píng)定統(tǒng)一標(biāo)準(zhǔn)》等。所以在施工中按照國(guó)家規(guī)定的規(guī)范標(biāo)準(zhǔn),建立一套完整的質(zhì)量評(píng)定管理體系是對(duì)強(qiáng)化施工管理工作十分有效的措施。質(zhì)量評(píng)定管理體系主要是按照給排水施工程序來(lái)進(jìn)行質(zhì)量評(píng)定的。包括以下內(nèi)容:1、施工中是否按照《管道支吊架安裝標(biāo)準(zhǔn)圖冊(cè)》進(jìn)行正確的管道安裝,并且確保所使用的管道材料的質(zhì)量與尺寸的標(biāo)準(zhǔn)匹配。主要是在評(píng)定過(guò)程中檢測(cè)管道試驗(yàn)壓力及介質(zhì)是否按照設(shè)計(jì)圖紙以及施工規(guī)范的施工計(jì)劃進(jìn)行,并且在水管、雨水管安裝項(xiàng)目進(jìn)行過(guò)程中實(shí)施灌水試驗(yàn),確定管道流通順暢。2、嚴(yán)格按照《建筑設(shè)計(jì)防火規(guī)范》GBJ16-87(2001版)所要求的建筑給排水系統(tǒng)規(guī)定進(jìn)行濕式噴淋消防工程質(zhì)量評(píng)定。在評(píng)定過(guò)程中應(yīng)該注意在建筑中的消火栓給水系統(tǒng)應(yīng)該按照規(guī)定的減壓處必須增設(shè)減壓孔板等有效的減壓裝置。這樣會(huì)防止消火栓栓口的靜水壓力過(guò)大問題。并且進(jìn)行消火栓栓口出水壓力測(cè)試。當(dāng)消防栓栓口P出>0.5Mpa時(shí),就應(yīng)該增設(shè)減壓孔板等減壓裝置。當(dāng)P靜>0.8Mpa的情況下,就應(yīng)該督促進(jìn)行分區(qū)給水系統(tǒng)的施工方法。3、在質(zhì)量評(píng)定管理中還要注意管網(wǎng)試壓工作。在管網(wǎng)試壓中要分別注意開展強(qiáng)度試驗(yàn)和嚴(yán)密性試驗(yàn)的工作。質(zhì)量評(píng)定管理工作要定期定時(shí)的進(jìn)行,對(duì)一些沒有按照施工規(guī)范進(jìn)行施工的情況,要及時(shí)進(jìn)行處理。并且設(shè)立給排水施工過(guò)程中的施工應(yīng)急機(jī)制,做到施工質(zhì)量管理中的未雨綢繆,防患于未然。
三、嚴(yán)格審查施工圖、優(yōu)化計(jì)算方法
對(duì)于施工圖的嚴(yán)格審查是施工質(zhì)量管理與控制的一項(xiàng)重要內(nèi)容。在施工圖審查中應(yīng)該按照施工現(xiàn)場(chǎng)的實(shí)際情況來(lái)進(jìn)行修改,以及計(jì)算方法的優(yōu)化。在施工圖審查過(guò)程中應(yīng)注意以下幾點(diǎn):1、施工圖應(yīng)按照《建筑工程設(shè)計(jì)文件》的有關(guān)規(guī)定進(jìn)行編制;2、施工圖紙資料應(yīng)盡量全面以便保證施工中的需要;3、施工圖紙中的計(jì)算方法應(yīng)適合施工的需求。對(duì)于所需要的管道設(shè)備型號(hào)以及設(shè)計(jì)坡度、等需要加以重視;4、施工設(shè)計(jì)圖紙中所提到的技術(shù)要求應(yīng)與施工實(shí)際情況相符合。設(shè)并且要符合施工技術(shù)要求。在嚴(yán)格審查施工圖過(guò)程中需要重新對(duì)管徑、水頭、泵的揚(yáng)程等各項(xiàng)指標(biāo)進(jìn)行檢驗(yàn)。特別是排水系統(tǒng)排水設(shè)計(jì)秒流量計(jì)算算法,設(shè)計(jì)中要注重對(duì)住宅、集體宿舍、醫(yī)院、等公共建筑與工業(yè)企業(yè)進(jìn)行區(qū)分。對(duì)于雨量系統(tǒng)的計(jì)算應(yīng)該按照、的公式進(jìn)行計(jì)算,其中Q為屋面雨水設(shè)計(jì)流量L/s;N為屋面設(shè)計(jì)匯水面積,m2;q5為當(dāng)?shù)亟涤?min內(nèi)的暴雨強(qiáng)度,L/(s?104m2);g5代表當(dāng)?shù)亟涤?min內(nèi)的小時(shí)降雨厚度,mm/h;h1代表設(shè)計(jì)重現(xiàn)期為一年時(shí)的屋面泄雨水的能力系數(shù)。泄雨水能力系數(shù)要根據(jù)生產(chǎn)工藝和建筑物的性質(zhì)確定,在給排水設(shè)計(jì)手冊(cè)中查出。
四、嚴(yán)格把關(guān)施工工序、按部就班保證施工質(zhì)量
為了加強(qiáng)施工質(zhì)量的管理與控制,施工時(shí)要嚴(yán)格的按照安裝的程序進(jìn)行施工,并且在施工不能按照程序進(jìn)行的時(shí)候,要及時(shí)的找出存在的問題,協(xié)調(diào)好施工中碰到的問題,做好施工中的檢查、記錄等。規(guī)范的施工程序應(yīng)當(dāng)有以下幾個(gè)步驟:1、預(yù)留洞的施工;2、給水管道的施工其中包括了管道連接、管道安裝、支架等施工工序3、排水管道施工4、隱蔽工程等內(nèi)容。
尹秀榮淺談高層樓房地下室防水施工方法[期刊論文]-科技致富向?qū)?2010(18)
金生建筑工程室外給排水施工質(zhì)量控制要點(diǎn)及對(duì)策[期刊論文]-中國(guó)對(duì)外貿(mào)易(英文版) 2010(22)
關(guān)鍵詞:建筑工程;施工;步驟;管理
Abstract: The ultimate goal of the management is to reduce loss and improve the efficiency, this article from the building construction technology management steps and strategy expounds the relevant content, I hope to help the development of industry.
Key words: construction project; construction management; step;
中圖分類號(hào):TU7文獻(xiàn)標(biāo)識(shí)碼: A 文章編號(hào):2095-2104(2012)05-0020-02
1 建筑工程施工技術(shù)管理的步驟
首先,現(xiàn)場(chǎng)布置圖必須根據(jù)場(chǎng)地實(shí)際合理地進(jìn)行布置,設(shè)施設(shè)備按現(xiàn)場(chǎng)布置圖規(guī)定設(shè)置堆放,并隨施工基礎(chǔ)、結(jié)構(gòu)、裝飾等不同階段進(jìn)行場(chǎng)地布置和調(diào)整。道路暢通、平坦、整潔,用混凝土澆搗,不亂堆亂放,無(wú)散落物;建筑物周圍應(yīng)澆搗散水坡,四周保持清潔;場(chǎng)地平整不積水,無(wú)散落的雜物及散物;場(chǎng)地排水成系統(tǒng),并暢通不堵。建筑垃圾必須集中堆放,及時(shí)處理。凡市區(qū)沿道路的建筑工地周圍,應(yīng)設(shè)置不低于2.5m的圍墻,圍墻兩面刷白。外面涂上建筑物名稱、建設(shè)單位、施工單位、設(shè)計(jì)單位、監(jiān)理單位等內(nèi)容。
其次在施工階段要注意施工步驟和思路方法:例如在施工中要明確以下工作思路1、現(xiàn)場(chǎng)勘查,確定施工方案;2、測(cè)量定位方線;3、土方清理車輛,現(xiàn)場(chǎng)清理平整;4、現(xiàn)場(chǎng)排水降水;5熟悉圖紙,技術(shù)交底,行使崗位責(zé)任制。然后要進(jìn)行控制挖方標(biāo)高軸線標(biāo)高的復(fù)核,最后執(zhí)行GBJ201-83規(guī)范、GBJ300-88規(guī)范、GBJ301-88規(guī)范、GBJ123-88規(guī)范所確定的質(zhì)量評(píng)定標(biāo)準(zhǔn)。在后期要做好測(cè)量定位記錄、驗(yàn)槽記錄、隱蔽工程驗(yàn)收記錄、質(zhì)量檢查和驗(yàn)收記錄等得具體工作,嚴(yán)格執(zhí)行相關(guān)的技術(shù)規(guī)范。
最后,盡量減少人工操作,盡量采用技術(shù)性措施,優(yōu)化工作手段,將人工的松弛、懈怠影響降到最低。例如對(duì)人工混凝土的振搗,僅僅依靠人為施工會(huì)造成之地不密實(shí),不如改成采用自動(dòng)化高拋免振化輔佐以人工的方法,以取得更好的效果。同時(shí)有計(jì)劃的將成本控制和施工進(jìn)度結(jié)合起來(lái),制定符合實(shí)際情況的管理方式方法。這兩點(diǎn)這才是建筑施工管理優(yōu)化的重中之重
2 明確建筑工程施工技術(shù)管理任務(wù)與作用
首先技術(shù)管理工作的主要任務(wù),是運(yùn)用管理的職能與科學(xué)的方法,使施工中正確貫徹國(guó)家的技術(shù)政策和上級(jí)有關(guān)技術(shù)工作的指示與決定,科學(xué)地組織各項(xiàng)技術(shù)工作,建立良好的技術(shù)秩序,保證生產(chǎn)過(guò)程符合技術(shù)規(guī)范、規(guī)程,符合技術(shù)規(guī)律的要求,以達(dá)到高質(zhì)量的全面完成施工任務(wù)的目的,使技術(shù)與經(jīng)濟(jì)、質(zhì)量與進(jìn)度、生產(chǎn)與技術(shù)達(dá)到辯證的統(tǒng)一。技術(shù)管理在整個(gè)企業(yè)管理工作中的作用,主要有以下幾個(gè)方面:一是尊重科學(xué)技術(shù)和科學(xué)技術(shù)發(fā)展規(guī)律,保證施工中按規(guī)律要求,按正常施工程序進(jìn)行,決不顛倒工序,破壞施工規(guī)律,如在建筑工程施工中,一般是先地下后地上,先主體后裝飾,主體工程自下而上,裝飾工程自上而下,另外還要充分考慮電氣、采暖、給排水、通風(fēng)、空調(diào)、電梯等安裝工程的配合穿插施工,做到預(yù)埋、預(yù)留的位置、尺寸準(zhǔn)確,安裝調(diào)試到位,使整體工程有條不紊地進(jìn)行。在裝飾工程的頂棚抹灰與樓地面工程的施工中,應(yīng)該是先施工樓地面工程,之后再進(jìn)行頂棚抹灰,因?yàn)闃堑孛婀こ痰氖┕すに囀牵呵謇砘鶎莹D――抄平彈線―――澆水濕潤(rùn)―――刷結(jié)合層―――澆筑混凝土基層。澆水濕潤(rùn)易造成頂棚污染,水的凝聚滲透作用降低抹灰層與混凝土結(jié)合層之間的粘結(jié)力,造成頂棚空鼓、裂縫、反堿。澆筑混凝土基層時(shí)施工機(jī)械和人為因素產(chǎn)生的振動(dòng)將造成頂棚抹灰層順預(yù)制板縫開裂和抹灰層空裂。這就說(shuō)明了施工技術(shù)管理中施工程序的重要性;二是通過(guò)技術(shù)管理,不斷提高企業(yè)管理水平和職工技術(shù)素質(zhì),能預(yù)見性地發(fā)現(xiàn)和處理問題,把技術(shù)和質(zhì)量隱患消滅在發(fā)生之前,從而達(dá)到不斷提高工程質(zhì)量的目的。
3 加強(qiáng)建筑工程施工技術(shù)管理的策略
3.1 施工準(zhǔn)備階段施工技術(shù)管理
首先,正確貫徹執(zhí)行黨和國(guó)家的各項(xiàng)技術(shù)政策,技術(shù)標(biāo)準(zhǔn)和技術(shù)規(guī)程,工程技術(shù)標(biāo)準(zhǔn)是建筑工程質(zhì)量和安全的最基本保障,是工程建設(shè)領(lǐng)域的技術(shù)法規(guī),要加強(qiáng)對(duì)強(qiáng)制性條文標(biāo)準(zhǔn)的培訓(xùn),增強(qiáng)掌握標(biāo)準(zhǔn)、執(zhí)行標(biāo)準(zhǔn)的能力。對(duì)違反強(qiáng)制性標(biāo)準(zhǔn)的行為必須按規(guī)定嚴(yán)厲處罰。建立技術(shù)管理體系,制定技術(shù)、質(zhì)量管理制度的同時(shí),明確各級(jí)、各崗位技術(shù)責(zé)任制。強(qiáng)化落實(shí),明確各級(jí)人員的責(zé)、權(quán)、利,企業(yè)主管要支持總工程師做出的正確決定。組織全體管理層、操作層,特別是技術(shù)管理人員學(xué)習(xí)現(xiàn)行標(biāo)準(zhǔn)、規(guī)程、圖集,尤其是對(duì)施工質(zhì)量驗(yàn)收規(guī)范的學(xué)習(xí),明確施工中每個(gè)檢驗(yàn)批、分項(xiàng)、分部施工技術(shù)要求、施工方法和質(zhì)量標(biāo)準(zhǔn)等要求,并以此來(lái)組織施工、檢查、評(píng)定和驗(yàn)收。確保能夠?qū)ΜF(xiàn)場(chǎng)出現(xiàn)的各種技術(shù)問題進(jìn)行及時(shí)、準(zhǔn)確的解決,把設(shè)計(jì)圖紙準(zhǔn)確地實(shí)施于現(xiàn)場(chǎng)。還有,理解設(shè)計(jì)意圖和關(guān)鍵部位的施工方法及質(zhì)量要求是技術(shù)管理的關(guān)鍵。一定要通過(guò)熟悉施工圖紙,了解施工項(xiàng)目設(shè)計(jì)圖紙說(shuō)明是否齊全;建筑結(jié)構(gòu)與各專業(yè)圖紙本身是否有差錯(cuò)及矛盾;標(biāo)高是否相一致、是否表示清楚、預(yù)埋件是
否表示清楚;工藝管道、電氣管道線是否合理。通過(guò)組織各專業(yè)人員熟悉、審查圖紙,參加圖紙會(huì)審,并從便于施工、加快進(jìn)度、保證質(zhì)量、降低成本等方面綜合考慮,提出合理化建議等。并編制施工組織設(shè)計(jì)或施工方案指導(dǎo)施工,每一個(gè)分項(xiàng)、分部都要進(jìn)行有針對(duì)性的安全技術(shù)交底,專業(yè)性強(qiáng)的、高危場(chǎng)所施工必須有專項(xiàng)施工方案及專項(xiàng)技術(shù)交底。
3.2 施工階段的施工技術(shù)管理
施工階段的技術(shù)管理應(yīng)該注重技術(shù)交底,保證工程質(zhì)量和進(jìn)度,同時(shí)控制工程成本。首先,技術(shù)交底是一項(xiàng)不容忽視的重要工作。對(duì)保證工程施工進(jìn)度和工程質(zhì)量至關(guān)重要。整個(gè)工程施工,各分項(xiàng)、分部工程,均需進(jìn)行及時(shí)準(zhǔn)確的技術(shù)交底。特殊和隱蔽工程,更應(yīng)加強(qiáng)技術(shù)交底工作,應(yīng)強(qiáng)調(diào)易發(fā)生質(zhì)量事故的部位和成品保護(hù)以及原材料、半成品方面的要求、安全功能特征施工技術(shù)要求。由于工程質(zhì)量主要表現(xiàn)在材質(zhì)、施工工藝、施工過(guò)程及成品保護(hù)等多方面。在對(duì)重要工程或采用新工藝、新技術(shù)設(shè)計(jì)的工程施工時(shí),應(yīng)成立 QC攻關(guān)小組,及時(shí)解決施工中的技術(shù)難題,同時(shí)現(xiàn)場(chǎng)實(shí)施樣板引路,每一個(gè)檢驗(yàn)批施工前依據(jù)技術(shù)交底進(jìn)行施工,專業(yè)工長(zhǎng)(質(zhì)檢員)依據(jù)技術(shù)交底進(jìn)行檢查,達(dá)到要求后方可大面積施工,上一道工序不合格決不允許下道工序施工,保證工程質(zhì)量。原材料、成品材料及半成品材料進(jìn)場(chǎng)應(yīng)嚴(yán)格實(shí)行質(zhì)量控制。施工中因管理失誤造成的工程質(zhì)量問題,不論其問題嚴(yán)重與否,都應(yīng)認(rèn)真對(duì)待,制定處理方案,使之引以為戒。所以技術(shù)管理必須按照規(guī)定的進(jìn)度目標(biāo),全面執(zhí)行施工進(jìn)度計(jì)劃。針對(duì)某些工作的實(shí)際進(jìn)度,及時(shí)調(diào)整好后續(xù)工作的進(jìn)度計(jì)劃安排;對(duì)交叉作業(yè),與其他專業(yè)工序相互銜接關(guān)系的工序優(yōu)先施工,一旦出現(xiàn)搶工期現(xiàn)象互不影響,各工種互創(chuàng)工作面;隨時(shí)注意工程形象、進(jìn)度以及施工能力、設(shè)備、材料供應(yīng)情況。對(duì)有分包的工程項(xiàng)目,應(yīng)注意協(xié)調(diào)各方有工序銜接關(guān)系的工作面的施工。
3.3 竣工階段技術(shù)管理
把握工程質(zhì)量的驗(yàn)收和評(píng)定。一個(gè)工程項(xiàng)目完工后,必須對(duì)其質(zhì)量進(jìn)行全面的客觀的驗(yàn)收評(píng)定,質(zhì)量驗(yàn)收評(píng)定是在施工管理中進(jìn)行,并且是以各分項(xiàng)工程的質(zhì)量來(lái)綜合鑒定分部工程的質(zhì)量,以各分部工程的質(zhì)量來(lái)鑒定單位工程的質(zhì)量?,F(xiàn)場(chǎng)施工管理應(yīng)認(rèn)真、仔細(xì)、嚴(yán)格把關(guān),對(duì)分項(xiàng)工程的質(zhì)量保證項(xiàng)目、檢驗(yàn)項(xiàng)目和實(shí)測(cè)項(xiàng)目應(yīng)盡力進(jìn)行檢查,施工過(guò)程中技術(shù)資料是否齊備,工程質(zhì)量是否達(dá)標(biāo),達(dá)不到合格標(biāo)準(zhǔn)的不予以驗(yàn)收。工程施工質(zhì)量的驗(yàn)收和評(píng)定是衡量企業(yè)和項(xiàng)目經(jīng)理管理水平高低的關(guān)鍵。
結(jié)束語(yǔ)
綜上所述,建筑工程施工技術(shù)管理在工程項(xiàng)目實(shí)施中呈面極其重要的地位,我們不僅要努力做好各項(xiàng)工作,還要與其它方面協(xié)調(diào)一致、相輔相成。從而使技術(shù)管理工作不斷得到完善和提高,為工程項(xiàng)目的順利實(shí)施提供可靠的技術(shù)保障。施工管理無(wú)論從哪個(gè)方面來(lái)講,在企業(yè)管理中都是如此重要,要想在競(jìng)爭(zhēng)的市場(chǎng)中站穩(wěn)腳步,必須從施工技術(shù)管理入手,企業(yè)才會(huì)有條不紊地進(jìn)行生產(chǎn),才會(huì)有更大的經(jīng)濟(jì)效益,才會(huì)有信譽(yù),才能更好地生存,才會(huì)有更大的發(fā)展。
參考文獻(xiàn)
[1]周衛(wèi).現(xiàn)場(chǎng)施工技術(shù)管理初探[J].廣西城鎮(zhèn)建設(shè),2010,3.
[2]景颯;鮑綏意;;廣安大街SMA路面施工技術(shù)[A];土木工程與高新技術(shù)――中國(guó)土木工程學(xué)會(huì)第十屆年會(huì)論文集[C];2002年
[3]陳貴喜;郝國(guó)文;陳春林;;尼爾基水利樞紐碾壓式瀝青混凝土心墻施工[A];第八次水利水電地基與基礎(chǔ)工程學(xué)術(shù)會(huì)議論文集[C];2006年
[4]孫新忠;張珍;;現(xiàn)澆混凝土防滲弧形底梯形渠施工機(jī)械研制及施工技術(shù)[A];中國(guó)水利學(xué)會(huì)首屆青年科技論壇論文集[C];2003年
[5]龐增勇.建筑工程施工技術(shù)管理的探討[J].科技信息,2009,7.
關(guān)鍵詞:住宅樓給排水;施工項(xiàng)目;質(zhì)量控制;影響因素;質(zhì)量控制策略
Abstract: water supply and drainage construction project in the construction of residential building in an important position, in order to improve the quality of the buildings, and promote people's living standard, in water supply and drainage construction project quality control work needed to be done. Influence of residential building water supply and drainage construction project quality factors include human factors, raw materials and construction method, etc. In the future, in the residential building water supply and drainage construction project quality control. The need to take the corresponding strategy, clear quality control links, and the residential building water supply and drainage construction project quality management of the whole process.
Keywords: residential building water supply and drainage; Construction projects; Quality control; Influencing factors; Quality control strategy
中圖分類號(hào):O213.1文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):
一、引言
近年來(lái),隨著我國(guó)建筑工程技術(shù)不斷發(fā)展,人們對(duì)現(xiàn)代化商品住宅樓的要求越來(lái)越高,同時(shí),對(duì)給排水系統(tǒng)的要求也相應(yīng)的提高。目前給排水管道多,在安裝和施工過(guò)程中存在著很多的問題,在實(shí)踐中,缺乏對(duì)住宅樓給排水施工項(xiàng)目的質(zhì)量控制。文章主要探討分析了住宅樓給排水施工項(xiàng)目質(zhì)量影響因素,并就住宅樓給排水施工項(xiàng)目質(zhì)量控制提出了相應(yīng)的策略,希望能夠引起人們對(duì)這一問題的進(jìn)一步關(guān)注,能夠?qū)?shí)踐起到指導(dǎo)作用。
二、住宅樓給排水施工項(xiàng)目質(zhì)量控制概述
住宅樓給排水施工項(xiàng)目質(zhì)量控制是指在住宅樓的建設(shè)中,按照相關(guān)的規(guī)定和標(biāo)準(zhǔn),對(duì)給排水系統(tǒng)進(jìn)行合理的安裝和控制,從而使整個(gè)給排水系統(tǒng)滿足保證用水量和水壓穩(wěn)定的要求。為了使給排水系統(tǒng)達(dá)到這個(gè)要求,在施工中需要按照施工流程,在設(shè)計(jì)階段、施工階段、使用階段對(duì)項(xiàng)目質(zhì)量進(jìn)行管理和控制。文中所探討的是指給排水工程施工項(xiàng)目的質(zhì)量控制。具體包括施工前準(zhǔn)備階段、工程實(shí)施階段和工程竣工驗(yàn)收階段的質(zhì)量控制。由于各階段對(duì)給排水的施工要求不同,質(zhì)量控制方法和要求不盡相同,所以,在各個(gè)階段,要根據(jù)施工的特點(diǎn),采取相應(yīng)的措施,實(shí)現(xiàn)對(duì)給排水施工項(xiàng)目的全程控制和管理。
此外,給排水施工項(xiàng)目必須按照國(guó)家的標(biāo)準(zhǔn)進(jìn)行,符合相關(guān)的規(guī)范,從而實(shí)現(xiàn)對(duì)工程質(zhì)量的控制。事實(shí)上,影響給排水施工項(xiàng)目質(zhì)量的因素很多,施工人員、施工材料、施工設(shè)備、施工方法、管理方式、施工環(huán)境都會(huì)對(duì)給排水施工項(xiàng)目質(zhì)量產(chǎn)生影響。所以,為了對(duì)住宅樓給排水施工項(xiàng)目質(zhì)量進(jìn)行控制,我們必須綜合考慮這些因素,建立完善的質(zhì)量標(biāo)準(zhǔn)體系和完善的管理體系,對(duì)其進(jìn)行嚴(yán)格的控制和管理,從而實(shí)現(xiàn)對(duì)住宅樓給排水施工項(xiàng)目質(zhì)量的控制。
三、住宅樓給排水施工項(xiàng)目質(zhì)量影響因素分析
住宅樓給排水施工項(xiàng)目質(zhì)量影響因素很多,總的來(lái)說(shuō),包括以下幾點(diǎn)。
1、人為影響因素。住宅樓給排水施工項(xiàng)目離不開人的參與,在施工實(shí)踐中,人為因素會(huì)對(duì)影響住宅樓給排水施工項(xiàng)目質(zhì)量,比如設(shè)計(jì)者的設(shè)計(jì)水平、施工者的工藝水平、監(jiān)理人員的工程水平等,都會(huì)影響住宅樓給排水施工項(xiàng)目質(zhì)量。尤其是如果施工者的工藝精湛、素質(zhì)高、責(zé)任心強(qiáng),給排水施工項(xiàng)目質(zhì)量越有保障。
2、原材料的影響。原材料會(huì)對(duì)給排水施工質(zhì)量產(chǎn)生直接的影響,給排水施工項(xiàng)目的原材料主要包括黃沙、水泥、石子、施工配料、工程機(jī)械等,它們都會(huì)影響工程的質(zhì)量。如果原材料合格、質(zhì)量可靠,給排水施工質(zhì)量會(huì)更加有保障。反之,如果原材料不合格、質(zhì)量不可靠,必然會(huì)對(duì)給排水施工項(xiàng)目的質(zhì)量產(chǎn)生很多的不利影響。
3、施工方法的影響。施工方法也會(huì)影響住宅樓給排水施工項(xiàng)目質(zhì)量,目前,給排水項(xiàng)目建設(shè)施工方法有多種多樣,不同的施工方法會(huì)對(duì)項(xiàng)目質(zhì)量產(chǎn)生不同的影響。為了控制項(xiàng)目質(zhì)量,需要結(jié)合項(xiàng)目工程的實(shí)際情況取用恰當(dāng)?shù)氖┕し椒ā1热?,在施工現(xiàn)場(chǎng)環(huán)境下,不能采用下沉式給排水管道,因?yàn)槿绻捎眠@種排水管道,容易引起給排水管道的沉降,容易導(dǎo)致管道遭到破壞。由此可見,施工方法會(huì)對(duì)給排水施工項(xiàng)目質(zhì)量產(chǎn)生影響,所以,要采用恰當(dāng)?shù)氖┕し椒ǎ瑢?duì)住宅樓給排水施工項(xiàng)目質(zhì)量進(jìn)行管理和控制。
四、住宅樓給排水施工項(xiàng)目質(zhì)量控制策略
住宅樓給排水施工項(xiàng)目質(zhì)量受到多種因素的影響,為了對(duì)項(xiàng)目質(zhì)量進(jìn)行管理和控制,需要采取相應(yīng)的策略,根據(jù)住宅樓給排水施工項(xiàng)目的實(shí)際情況,結(jié)合其影響因素,筆者認(rèn)為應(yīng)該采取以下措施來(lái)對(duì)住宅樓給排水施工項(xiàng)目質(zhì)量進(jìn)行控制和管理。
1、加強(qiáng)源頭管理和控制。源頭控制主要表現(xiàn)在整頓和規(guī)范建材市場(chǎng),保證原材料的質(zhì)量。由于原材料對(duì)住宅樓給排水施工項(xiàng)目質(zhì)量的影響是直接的,所以,我們首先必須規(guī)范建材市場(chǎng),加強(qiáng)源頭控制和管理。具體措施可以是加強(qiáng)對(duì)建材市場(chǎng)的管理,規(guī)范生產(chǎn)經(jīng)營(yíng)秩序;重視對(duì)建材質(zhì)量的檢測(cè),防止不合格的產(chǎn)品流入市場(chǎng)和生產(chǎn)領(lǐng)域;加大執(zhí)法力度,嚴(yán)厲打擊制假售假行為,加大對(duì)制假售假行為的懲處力度。
2、強(qiáng)化過(guò)程控制,嚴(yán)格監(jiān)督管理。在施工之前,需要組織建設(shè)單位和參建單位參加工作交底會(huì)。在工程項(xiàng)目的建設(shè)過(guò)程中,監(jiān)督人員要做好監(jiān)督管理工作,加強(qiáng)對(duì)原材料、構(gòu)件材料、配件材料的檢測(cè),重視對(duì)關(guān)鍵部位和重要工序的質(zhì)量監(jiān)督管理與控制。
3、監(jiān)督交底,明確內(nèi)容。質(zhì)量監(jiān)督員需要制定具體的質(zhì)量監(jiān)督計(jì)劃書,并向施工單位宣布具體的施工方案和監(jiān)督管理要求,明確監(jiān)督程序,制定監(jiān)督標(biāo)準(zhǔn),對(duì)于需要抽查的內(nèi)容和強(qiáng)制執(zhí)行的標(biāo)準(zhǔn)進(jìn)行說(shuō)明。
4、對(duì)住宅樓給排水施工項(xiàng)目實(shí)施全過(guò)程的質(zhì)量跟蹤管理。第一、在施工前準(zhǔn)備階段,熟悉和審查圖紙、制定施工計(jì)劃、檢驗(yàn)材料和半成品的質(zhì)量、檢修施工設(shè)備、建立質(zhì)量控制體系等。第二、在施工階段重視質(zhì)量管理和質(zhì)量控制工作,做好施工技術(shù)交底、質(zhì)量檢查、質(zhì)量整改、質(zhì)量分析等。第三、在驗(yàn)收和交付階段,檢查工程的試運(yùn)行狀況,對(duì)施工資料進(jìn)行匯編,并總結(jié)施工經(jīng)驗(yàn)等等。只有整個(gè)過(guò)程的質(zhì)量得到了控制,住宅樓給排水施工項(xiàng)目質(zhì)量控制才有可能實(shí)現(xiàn)。
五、結(jié)束語(yǔ)
總之,住宅樓給排水施工質(zhì)量對(duì)住宅樓整體功能的發(fā)揮會(huì)產(chǎn)生重要的影響,要使住宅樓整體功能得到最大的發(fā)揮,就必須對(duì)給排水施工項(xiàng)目質(zhì)量進(jìn)行管理和控制。文章主要結(jié)合實(shí)際情況,探討分析了住宅樓給排水施工項(xiàng)目質(zhì)量的影響因素,并就施工項(xiàng)目質(zhì)量控制提出了相應(yīng)的策略。在實(shí)踐中,要想真正實(shí)現(xiàn)對(duì)住宅樓給排水施工質(zhì)量的控制,還需要各方面的共同努力。
參考文獻(xiàn):
[1]趙光春,魏峰.住宅樓給排水施工項(xiàng)目質(zhì)量控制研究[J].城市建設(shè)理論研究(電子版),2012(7)
[2]陶義,唐寧霞.住宅樓給排水施工項(xiàng)目質(zhì)量控制研究[J].科技傳播,2011(13)
關(guān)鍵詞:市政工程;施工技術(shù);研究
伴隨著國(guó)民經(jīng)濟(jì)的迅速發(fā)展,城市化水平的不斷提高,近年來(lái)我國(guó)市政工程的項(xiàng)目數(shù)量也在急劇增加,市政工程是市政公用設(shè)施的簡(jiǎn)稱,它包括城市道路、城市橋梁、城市軌道交通和隧道工程、城市給水排水工程、城市燃?xì)狻⒐岬裙艿拦こ?、生活垃圾填埋處理工程。市政工程施工技術(shù)與方法的作用在市政工程建設(shè)中發(fā)揮了重要的作用,只有充分了解市政工程的施工技術(shù)的內(nèi)容與方法,才能將市政工程建設(shè)推向一個(gè)新的高度。
一、道路工程的施工
(一)路基施工
對(duì)于路基施工基底的處理主要包括三個(gè)方面的主要內(nèi)容,一是對(duì)于基底的處理,路基的基底是路面施工的基礎(chǔ),也是道路的基礎(chǔ),路堤在清理之后所停留在路基表面的就是路基基底。對(duì)于路基的施工,一定要保證路基具有足夠強(qiáng)度(承載力)和低壓縮性以免引起滑動(dòng)破壞和過(guò)大沉降。二是路堤填筑,路堤填筑要堅(jiān)持分層平鋪,豎向填筑的原則。路堤填筑時(shí)還要注意強(qiáng)度的均勻度,為了增強(qiáng)路堤的結(jié)實(shí)度,通常會(huì)采用透水性較差的土壤填在路堤下面。三是對(duì)于填料的選擇,填料的選擇要堅(jiān)持就近取材的原則,盡量選取強(qiáng)度較高,壓縮性小,運(yùn)輸方便的巖石材料作為填料。
(二)路塹開挖
路塹開挖主要包括三種方式,一是縱向全寬掘進(jìn),二是橫向通道掘進(jìn),三是縱橫通道混合掘進(jìn)。三是縱橫通道混合掘進(jìn)就是在道路的兩端同時(shí)進(jìn)行道路施工和開挖,當(dāng)?shù)缆芬箅p層施工時(shí),下層要留有上層一些施工的足夠空間。這種路塹開挖的方式主要適應(yīng)于短而深的路塹進(jìn)行開挖。橫向通道掘進(jìn)即沿路塹縱向挖掘工作通道,再逐漸向兩側(cè)橫挖。本法可將高度分成幾個(gè)層次安排多組臺(tái)班在不同層次和前后錯(cuò)開的作業(yè)面上開挖,適用于開挖量大、較長(zhǎng)的路塹。縱橫通道混合掘進(jìn)。若開挖斷面寬,開挖量大,可在開挖縱向通道的基礎(chǔ)上再在橫向開挖通道,提高工作效率。僅限于人工施工。
(三)路基壓實(shí)
路基施工已經(jīng)將原有的土體結(jié)構(gòu)進(jìn)行破壞,為了維護(hù)土體的實(shí)態(tài),保證路基工程的順利進(jìn)行,必須對(duì)路基進(jìn)行壓實(shí)。路基壓實(shí)是路基施工過(guò)程中的一個(gè)重要環(huán)節(jié),也是提高道路施工質(zhì)量和安全穩(wěn)定性的重要舉措。正確選用壓實(shí)度,關(guān)系到土路基的受力狀態(tài)、路基路面設(shè)計(jì)要求、施工條件,必須兼顧需要與可能,講究實(shí)效與經(jīng)濟(jì)。
二、橋梁工程的施工
(一)橋梁基礎(chǔ)施工
1.明挖擴(kuò)大基礎(chǔ)施工
明挖擴(kuò)大基礎(chǔ)施工主要包括旱地基礎(chǔ)的基坑開挖和水中地基的基坑開挖。無(wú)論哪種開挖都應(yīng)避免超挖,遇到暴雨天氣注意設(shè)置截水溝或排水溝,基坑開挖至設(shè)計(jì)高程后,都不能長(zhǎng)時(shí)間暴露、擾動(dòng)或侵泡而削弱其承載能力。水中地基的基坑開挖主要包括圍堰、基坑排水和基坑挖基三個(gè)重要階段,因此水中低級(jí)開挖的難度較大,對(duì)于技術(shù)的要求也較高。
2.樁基礎(chǔ)施工
樁是橋的根基和基礎(chǔ),打好樁是架好橋的第一步。對(duì)于旱地打樁要嚴(yán)格控制好沉樁允許誤差,垂直樁的允許誤差是1%,斜樁的允許誤差是傾角正切約15%。對(duì)于水中樁基的施工可以采用鋼板樁圍堰法,即先圍堰后沉樁,先沉樁后圍堰順序。
(二)橋梁上部構(gòu)造施工
常用的市政工程中的橋梁上部施工方法有:支架法施工、頂推法施工和懸臂施工法。支架法施工的一般施工順序?yàn)榇钤O(shè)支架――安裝模板、鋼筋――就地澆筑梁體混凝土。這種施工方法的缺點(diǎn)是需要大量的支架和模板,但相比其他施工方法,這種施工方法比較經(jīng)濟(jì)、簡(jiǎn)單。頂推法是在沿橋梁縱軸方向的橋臺(tái)臺(tái)后設(shè)置預(yù)制平臺(tái),分段預(yù)制混凝土梁身并施加預(yù)應(yīng)力筋連成整體,然后通過(guò)水平液壓千斤頂施力,使梁體在各墩的滑道上逐段向前滑動(dòng),直至全連續(xù)梁頂推就位后,落梁、更換正式支座,完成橋梁施工。懸臂施工法是以橋墩為中心向兩岸對(duì)稱的、逐節(jié)懸臂接長(zhǎng)的施工方法。
(三)橋面系施工
橋面系――是橋梁橋跨體系上部許多附屬設(shè)施的統(tǒng)稱,主要包括:橋面鋪裝、人行道、欄桿或護(hù)欄、伸縮裝置等。橋面部分雖然不是主要承重結(jié)構(gòu),但它對(duì)橋梁功能的正常發(fā)揮、對(duì)主要構(gòu)件的保護(hù)、對(duì)車輛行人的安全以及橋梁的美觀等都十分重要,如果施工中出現(xiàn)質(zhì)量問題,會(huì)嚴(yán)重影響橋梁的使用性能。
三、管道工程的施工
(一)溝槽開挖與回填
1.溝槽開挖
(1)機(jī)械開挖
①在開挖溝槽時(shí)候。首先一定要確定好開挖的順序線路以及其他的參數(shù)系數(shù),另外開挖要符合相關(guān)的施工規(guī)范,以技術(shù)和管理作為施工的重要支撐。
②如果采用機(jī)械開挖的話,首先要做好交底工作,對(duì)工程施工的機(jī)械司機(jī)要進(jìn)行詳細(xì)的技術(shù)交底,只有他們充分了解開挖的要求后,才能保證施工的順利進(jìn)行。另外在開挖過(guò)程中要設(shè)置專人進(jìn)行施工的檢查,防止超挖或欠挖。
③挖土機(jī)沿挖方邊坡移動(dòng)時(shí),機(jī)械距邊坡上緣的寬度一般不得小于溝槽深度的1/2。
(2)人工開挖:在使用人工挖溝的過(guò)程中,一定要控制好開挖的深度,一般情況下,開挖深度不宜超過(guò)2m,如果開發(fā)較深或是不符合相關(guān)的人工開挖的規(guī)范就會(huì)產(chǎn)生安全隱患。
(3)溝槽支護(hù):溝槽的支護(hù)工作的溝槽開挖的一項(xiàng)重要防護(hù)工作,它可以有效的對(duì)溝槽進(jìn)行保護(hù),保證開挖的安全性。
2.溝槽回填
溝槽回填主要有兩種方式,一種是剛性管道的溝槽回填,采用這種回填方式要注意逐層進(jìn)行回填,在回填過(guò)程中切記不能對(duì)管道產(chǎn)生一定的損傷或是碰壞。第二種是柔性管道的溝槽回填,這種方式進(jìn)行回填之前要做好對(duì)管道的檢查工作,一旦發(fā)現(xiàn)管道出現(xiàn)問題,立即采取相應(yīng)措施進(jìn)行更換。
(二)城市給水、排水管道施工
城市的給水、排水管道施工是城市管道施工的重要組成部分,它們都是由由管道和相應(yīng)附屬物組成,在城市的給水、排水中都各自發(fā)揮著重要的作用。在進(jìn)行城市的給水、排水管道施工之前,首先要做好選用管材的工作,合理選用既合適而又經(jīng)濟(jì)的管型,降低施工成本。其次是要有效地控制好管道的位置即管位,對(duì)于雨水天氣或是積水較多的地區(qū)的管道施工要先設(shè)置驗(yàn)槽現(xiàn),再開挖槽。
結(jié)語(yǔ):當(dāng)然,市政工程的內(nèi)容還有很多,每一個(gè)內(nèi)容都將在市政工程建設(shè)中發(fā)揮著重要的作用,但是我們一定不能忽視任何一種工程的作用,但是只有充分的了解市政工程的各種施工技術(shù)的前提下,才能更好地建設(shè)市政工程,不斷地在實(shí)踐中去總結(jié)和發(fā)展原有的施工技術(shù),從而大大提高工程的質(zhì)量,節(jié)省更多的人力、財(cái)力、物力。
參考文獻(xiàn):
[1]葉永輝,梁永云,群. 市政工程造價(jià)控制與管理中的問題及措施[J]. 項(xiàng)目管理技術(shù). 2009(S1)
[2]張閩. 淺議市政工程施工中質(zhì)量的影響因素和項(xiàng)目質(zhì)量控制[J]. 沿海企業(yè)與科技. 2007(12)
[3]北京市建設(shè)委員會(huì)關(guān)于加強(qiáng)市政工程施工安全生產(chǎn)管理的通知[J]. 北京市人民政府公報(bào). 2006(23)
[4]潘學(xué)文. 確保市政給排水工程施工質(zhì)量的技術(shù)措施[J]. China’s Foreign Trade. 2011(16)
關(guān)鍵詞:多層住宅建筑;給排水;施工;技術(shù)
Abstract: any residential design, it is to be in the rational analysis of gradually ongoing innovation and perfect. Give full play to the advantages of multilayer residence alone, making it more than other architectural form can reflect the comforts of life, can live significance of the city ascend to a new level. This article mainly from the multilayer residence building water supply and drainage construction technology were discussed.
Keywords: multilayer residence building construction; Water supply and drainage; The construction; technology
中圖分類號(hào): TU74文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):
隨著城市的發(fā)展, 房?jī)r(jià)的高漲, 購(gòu)房者們居住理念的不斷成熟,人們?cè)谶x擇房子時(shí)在意的因素也越來(lái)越多。與高層住宅相比, 得房率較高、 公攤面積相對(duì)較少、 人居環(huán)境相對(duì)舒適的多層住宅更加受到人們的青睞。任何住宅設(shè)計(jì),都是需要在逐步的理性分析中不斷進(jìn)行創(chuàng)新和完善的。充分發(fā)揮多層住宅獨(dú)具的
優(yōu)勢(shì), 使其較之其他建筑形態(tài)更能體現(xiàn)出生活的舒適, 才能將城市的居住意義提升到嶄新的境界。
一、 給水系統(tǒng)采用豎向分區(qū)
由于建筑物高的特點(diǎn),凈水壓力大會(huì)產(chǎn)生嚴(yán)重弊端,所以采用豎向分區(qū),即在建筑物的垂直方向按一定高度依次分為若干個(gè)供水分區(qū),每個(gè)供水分區(qū)組成各自獨(dú)立的給水系統(tǒng)。當(dāng)采用高位水箱供水時(shí),一般就要把10―12層分為一個(gè)供水區(qū),當(dāng)采用高位水箱供水時(shí),各分區(qū)高位水箱要保證各分區(qū)最不利點(diǎn)衛(wèi)生器具或用水設(shè)備的流出水頭,其相對(duì)安裝高度,即水箱最低水位與該區(qū)最不利點(diǎn)衛(wèi)生器具或用水設(shè)備的垂直距離應(yīng)大于等于最不利點(diǎn)的流出水頭,雨水流流經(jīng)由水箱之最不利點(diǎn)管道和水表的水頭損失之和,其值一般約為100kPa左右。同時(shí),進(jìn)行豎向分區(qū)時(shí),應(yīng)充分利用市政管網(wǎng)的壓力,以減少供水所需的能耗。當(dāng)市政管網(wǎng)能夠滿足一部分樓層時(shí),如裙房、地下室以及游泳池、洗衣房、鍋爐房等用水需要,就充分利用。
二、給水管道材料的選擇
給水管道在材料的選擇上,除了需要考慮到經(jīng)濟(jì)實(shí)惠之外,還必須要考慮到技術(shù)設(shè)計(jì)上的需要,只有對(duì)其進(jìn)行綜合的分析比較,一方面使得其具有經(jīng)濟(jì)性,例如,如果是解困房或者經(jīng)濟(jì)適用房,那么可以選擇衛(wèi)生級(jí)的硬聚氯乙烯材料的管道作為給水管,以降低造價(jià),如果是相對(duì)高檔點(diǎn)的商品房,那么可以選擇鋁塑復(fù)合的管道作為給水管道,如果是更加高檔的住宅,可以利用薄壁的鋼管作為給水管道,根據(jù)不同的房屋等級(jí)及服務(wù)目標(biāo)來(lái)進(jìn)行選擇。 另一方面需要考慮的就是管道的安全性,連接的問題,拿塑料的同金屬的管道進(jìn)行對(duì)比,可以發(fā)現(xiàn)塑料管道具有很多的優(yōu)點(diǎn):質(zhì)量輕、沒有氣味和毒副作用噪音較低、 強(qiáng)度較高,而且使用的壽命長(zhǎng),但是其缺點(diǎn)就是膨脹系數(shù)大,需要支撐的管道多,所以在安裝的過(guò)程中,就要充分的考慮到管道的變形系數(shù),適當(dāng)?shù)倪h(yuǎn)離熱源,而金屬管道具有最明顯的優(yōu)點(diǎn)就是強(qiáng)度大,但是其不具有很好的耐腐蝕性和安全衛(wèi)生性,沒有塑料管道易于連接,因而在設(shè)計(jì)的過(guò)程中需要權(quán)衡考慮二者的優(yōu)缺點(diǎn),進(jìn)行合理的選擇;另外,在選材的時(shí)候,可以有效的進(jìn)行多種管材的組合,如室內(nèi)可選硬聚氯乙烯管(PVC-U )或高密度聚乙烯管,室外可選用鋼塑復(fù)合管或鋁塑復(fù)合管,熱水管可選用鋁塑復(fù)合管(PEX-AL-PEX )
三、給水管道施工措施
PPR給水管在做熱熔連接時(shí),要掌握好加熱時(shí)間和連接插入的深度。插入太深,造成管道斷面減少;插入太淺令接口處強(qiáng)度降低。溫度、加熱時(shí)間和接縫壓力是熱熔連接的三個(gè)關(guān)鍵因素。鋁塑復(fù)合管需要卡套式連接,其滲漏的主要原因是:O型橡膠圈和C型壓環(huán)套的相對(duì)位置沒有調(diào)整好,另有管口剪切不垂直、螺帽沒擰緊等原因。鋁塑復(fù)合管屬半軟性材料,公稱外徑De≤1.259 8in的管道,其轉(zhuǎn)彎時(shí)應(yīng)盡量利用管道自身直接彎曲,彎曲半徑不小于管外徑的5倍。對(duì)于直埋暗敷熱水管,為防止在轉(zhuǎn)彎段填塞的水泥砂漿出現(xiàn)裂紋,應(yīng)注意管槽砂漿填塞做法。鋼塑復(fù)合管需要采用螺紋連接時(shí),旋入配件的長(zhǎng)度應(yīng)嚴(yán)格按照標(biāo)準(zhǔn)旋入進(jìn)行控制;管端、管螺紋清理加工后,應(yīng)進(jìn)行防腐密封處理,采用防銹密封膠和聚四氟乙烯生料帶纏繞螺紋;外露的螺紋部分及所有鉗痕和表面損傷的部位均應(yīng)涂防銹密封膠;用厭氧密封膠密封的管接頭,需養(yǎng)護(hù)24 h以上才能試壓。采用專用施工機(jī)具,不能隨意替換。溝槽式連接要采用專用橡膠密封圈,不能用普通非襯塑鋼管連接所用的密封件代替。PEX給水管暗敷在地坪(含木地板)架空層內(nèi)的熱水管宜設(shè)防護(hù)套管,既起保護(hù)管道和隔熱保溫的作用,又便于更換管道。套管可采用硬聚氯乙烯波紋管。安裝De≤25 Inrn的管道時(shí),利用管道自身的可彎性能,不設(shè)或少設(shè)管道連接件,彎曲半徑(以管軸線計(jì))不得小于6De;90°轉(zhuǎn)彎時(shí)設(shè)金屬?gòu)澒軍A,并與管道固定牢靠。
四、水表戶外設(shè)置問題
水表設(shè)在戶內(nèi)不但增大了抄表的工作量而且使住宅的安全性和私密性大大降低,隨著電表熱表的相繼出戶,住宅的分戶水表或分戶水表的數(shù)字顯示也宜設(shè)在戶外,多層住宅水表戶外設(shè)置主要有以下兩種形式:(1)把普通水表(含熱水表)換成遠(yuǎn)傳水表由1根信號(hào)線連接水表與數(shù)據(jù)采集機(jī)再傳至智能管理(微機(jī))處,它的優(yōu)點(diǎn)在于節(jié)省大量人力抄表數(shù)據(jù)準(zhǔn)確,缺點(diǎn)是造價(jià)高,在物業(yè)管理完善的中高檔商品房住宅小區(qū)可采用遠(yuǎn)傳水表,它是今后水表應(yīng)用發(fā)展的方向。(2)對(duì)于大多數(shù)住宅可將普通水表設(shè)在戶外管道井內(nèi),水表集中設(shè)置(水表組)在底層,各層住戶給水支管在管道井內(nèi)敷設(shè),也可在建筑物陰角處沿外墻敷設(shè);這種方式增加給水支管敷設(shè)長(zhǎng)度、管道沿外墻敷設(shè)影響建筑物美觀,但工程造價(jià)低。水表出戶布置的方式選擇,須結(jié)合住宅廚房、衛(wèi)生間平面布置特點(diǎn)和開發(fā)商的具體要求 。
五、消火栓給水系統(tǒng)
高層建筑給水工程的特點(diǎn)之一就是對(duì)消防給水系統(tǒng)有較嚴(yán)格的要求。必須設(shè)置有足夠自救能力的,獨(dú)立的消防給水系統(tǒng)。包括:室內(nèi)、外消火栓給水系統(tǒng)和自動(dòng)噴水滅火系統(tǒng)等。
1、自動(dòng)噴水滅火系統(tǒng)
自動(dòng)噴水滅火系統(tǒng)是控制和撲滅初期火災(zāi)的有效設(shè)施。又可分為濕式系統(tǒng),干式系統(tǒng),預(yù)作用系統(tǒng),雨淋系統(tǒng)和水幕系統(tǒng)等。室外消防管網(wǎng)采用低壓制,呈環(huán)狀設(shè)置,共設(shè)四個(gè)地上式室外消火栓。室內(nèi)消防系統(tǒng)共設(shè)8套地上式水泵接合器,其中接消火栓系統(tǒng)6套,接自動(dòng)噴水系統(tǒng)2套。室內(nèi)消火栓系統(tǒng)用水量40l/s,火災(zāi)延續(xù)時(shí)間3小時(shí)。室內(nèi)消火栓給水管網(wǎng)成環(huán)狀布置。豎向分為四個(gè)個(gè)區(qū),每個(gè)區(qū)最低層消火栓口的靜水壓力不大于0.80MPa。消火栓口的出水壓力大于0.50MPa時(shí),采用減壓穩(wěn)壓消火栓。在地下一層設(shè)置消防水池。消防水池有效容積532m3,分為兩格。地下一層消防水泵房?jī)?nèi)設(shè)置消火栓加壓泵,高低區(qū)消防主泵均為三臺(tái),兩用一備。發(fā)生火災(zāi)時(shí)先啟動(dòng)一臺(tái)消防泵,當(dāng)供水壓力不能滿足要求時(shí)再啟動(dòng)第二臺(tái)消防泵。在屋頂設(shè)備房設(shè)消防專用氣壓供水設(shè)備,以保證最高幾層消防管網(wǎng)的壓力。各層消火栓設(shè)置保證防護(hù)面積內(nèi)任何部位有兩個(gè)消火栓的水槍充實(shí)水柱同時(shí)到達(dá),充實(shí)水柱為13m。 轉(zhuǎn)貼于 中國(guó)論文下載
2、室內(nèi)外消火栓給水系統(tǒng)
高層建筑室內(nèi)、外消火栓給水系統(tǒng),是高層建筑最基本的滅火設(shè)備。室內(nèi)除設(shè)置普通消火栓外,一般都同時(shí)設(shè)置小口徑消火栓,也叫自救式消火栓或水喉。
六、雨水排水系統(tǒng)
位于住戶上部的屋面,雨水斗不能采用65型或87型雨水斗(雨水橫管不能走在住宅內(nèi)部),而應(yīng)用側(cè)墻式雨水斗。但在用側(cè)墻式雨水斗時(shí)其最大匯水面積不能選用《建筑給水排水設(shè)計(jì)手冊(cè)》表4.3―3的數(shù)值,而應(yīng)按《屋面工程技術(shù)規(guī)程》(GB50207―94)第4.3.10條的規(guī)定,一個(gè)側(cè)墻式雨水斗最大匯水面積宜小于200m2。陽(yáng)臺(tái)雨水應(yīng)設(shè)專用的立管由無(wú)水封地漏來(lái)收集,而不應(yīng)接到屋面雨水立管上。將陽(yáng)臺(tái)雨水地漏接到屋面雨水立管下部正壓區(qū),則有返水倒灌的可能,在實(shí)際工程中發(fā)生的頻率是很高的。有的城市為了解決住戶將廚房洗滌盆移到服務(wù)陽(yáng)臺(tái)并將洗滌污水排到陽(yáng)臺(tái)地漏內(nèi)的問題,由建設(shè)局下文要求將陽(yáng)臺(tái)雨水立管排到污水檢查中,這種規(guī)定是不安全的。對(duì)于起居室及臥室的陽(yáng)臺(tái)是不存在有污水的排入,陽(yáng)臺(tái)雨水地漏是無(wú)水封的,即使采用有水封的地漏,水封由于長(zhǎng)時(shí)間得不到補(bǔ)充,會(huì)逐漸蒸發(fā)掉,污水系統(tǒng)內(nèi)的廢氣就會(huì)流到起居室內(nèi),污染環(huán)境,所以要根據(jù)建筑物特點(diǎn)來(lái)設(shè)計(jì)。
參考文獻(xiàn):
[1] 高秋柏, 宋雨雨. 淺談多層住宅建筑給排水施工技術(shù)[J]. 黑龍江科技信息, 2011,(16)
[2] 王文華. 給排水管道的技術(shù)經(jīng)濟(jì)性分析[J]. 科技風(fēng), 2009,(16)
[3] 楊梅花. 新型給排水管道技術(shù)經(jīng)濟(jì)比較淺析[J]. 科技風(fēng), 2011,(09)
[4] 蔣中伯. 綜述城市基礎(chǔ)設(shè)施中的給排水管道施工[J]. 科技風(fēng), 2011,(05)
摘要:監(jiān)理項(xiàng)目全過(guò)程控制是一個(gè)有機(jī)整體。但是從工作內(nèi)容來(lái)看又由若干環(huán)節(jié)組成一個(gè)整體。根據(jù)各個(gè)環(huán)節(jié)的不同特點(diǎn)和工作內(nèi)容,采取相應(yīng)的措施與手段,環(huán)環(huán)扣緊,條條落實(shí),是監(jiān)理工程師實(shí)施項(xiàng)目施工全過(guò)程控制的重要職責(zé)之所在。本文結(jié)合本人的工作經(jīng)驗(yàn),主要從監(jiān)理施工在工程中的應(yīng)用;監(jiān)理需要加強(qiáng)管理工作,以及控制工程整體質(zhì)量方面進(jìn)行簡(jiǎn)述。 關(guān)鍵詞:土建工程;監(jiān)理;基礎(chǔ)施工;主體施工;管理要點(diǎn)
Abstract: the whole project supervision control is an organic whole. But from the working content to see and some link by an integral unit. According to the different characteristics of each link and working content and adopt corresponding measures and means, HuanHuan fasten, all roads implemented, the implementation of project construction supervision engineer is the important functions of the entire process control of the serengeti. This paper based on his own experience of work, mainly from the application in engineering construction supervision; Supervision need strengthening the management, and control engineering overall quality aspects of this.
Keywords: civil engineering; Supervision; Foundation construction; Subject construction; Management guidelines
中圖分類號(hào):U415.1 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào)1 施工前期準(zhǔn)備 1.1 嚴(yán)把圖紙會(huì)審關(guān),積極組織施工、設(shè)計(jì)、監(jiān)理各專業(yè)技術(shù)人員共同對(duì)圖紙進(jìn)行會(huì)審。
通過(guò)圖紙會(huì)審可以使各參建單位特別是施工單位熟悉設(shè)計(jì)圖紙、領(lǐng)會(huì)設(shè)計(jì)意圖、掌握工程特點(diǎn)及難點(diǎn),找出需要解決的技術(shù)難題并擬定解決方案,從而將因設(shè)計(jì)缺陷而存在的問題消滅在施工之前。因此,圖紙會(huì)審的深度和全面性將在一定程度上影響工程施工的質(zhì)量、進(jìn)度、成本、安全和工程施工的難易程度。只要認(rèn)真做好了此項(xiàng)工作,圖紙中存在的問題一般都可以在圖紙會(huì)審時(shí)被發(fā)現(xiàn)并盡早得到處理,從而可以提高施工質(zhì)量、節(jié)約施工成本、縮短施工工期,提高效益。因此,圖紙會(huì)審是工程施工前的一項(xiàng)必不可少的重要工作。
目前會(huì)審工作存在的弊病是:水、電、土建分組會(huì)審后匯總,缺少專業(yè)之間的會(huì)審;施工單位的土建、安裝分設(shè)技術(shù)負(fù)責(zé)人而無(wú)總工整體把關(guān);設(shè)計(jì)單位按照專業(yè)繪圖設(shè)計(jì),缺少專業(yè)審查。各單位均應(yīng)安排技術(shù)負(fù)責(zé)人在圖紙會(huì)審基礎(chǔ)上對(duì)此嚴(yán)格審核。 1.2 把建筑、結(jié)構(gòu)、給排水、消防圖紙審查意見書及圖紙會(huì)審紀(jì)要內(nèi)容注解于相應(yīng)施工圖;避免施工時(shí)遺漏造成返工事件。 2 基礎(chǔ)施工階段 2.1 根據(jù)設(shè)計(jì)及業(yè)主確定的±0.000標(biāo)高,及時(shí)核給排水、消防系統(tǒng)管道標(biāo)高與現(xiàn)有場(chǎng)地標(biāo)高是否符合凍土層深度,以免對(duì)此不進(jìn)行復(fù)核而造成給排水系統(tǒng)受凍。 2.2 基礎(chǔ)筏板、條基施工時(shí)應(yīng)在鋼筋綁扎時(shí)通知安裝隊(duì)伍進(jìn)行接地裝置施工,復(fù)核接地裝置正確無(wú)誤,土建安裝監(jiān)理人員共同簽字確認(rèn)后方可進(jìn)行澆筑。 2.3 地下室墻板施工支模之前,要求施工單位選擇并報(bào)審分包單位及安裝單位進(jìn)場(chǎng),避免造成諸如設(shè)有地下通風(fēng)系統(tǒng)而土建圖未標(biāo)洞口,而通風(fēng)施工單位未確定,澆筑后發(fā)現(xiàn)通風(fēng)系統(tǒng)洞口未進(jìn)行預(yù)留等尷尬局面。 2.4 認(rèn)真復(fù)核電氣進(jìn)線管、排水出口、給水進(jìn)口標(biāo)高是否與圖紙相符并檢查設(shè)置套管是否符合要求,固定是否牢固;征得土建及安裝監(jiān)理工程師同意后才允許合模和澆筑,并且要求給班組書面交底,加強(qiáng)對(duì)安裝管口的保護(hù)。 2.5 實(shí)行±0.000現(xiàn)澆板首層會(huì)審制,避免給排水、衛(wèi)生器具在平面位置上與建筑相矛盾?!?.000現(xiàn)澆板澆筑前應(yīng)檢查排水立管位置與通風(fēng)管道、窗、土建上層梁的影響及觀感,衛(wèi)生器具位置是否與門、電氣開關(guān)、插座相矛盾,開關(guān)的位置是否使用方便(有的設(shè)計(jì)開關(guān)位置在門后);給水管道是否與采暖、排水管道相互影響,做到事前控制,以滿足使用方便美觀為原則。 2.6 在現(xiàn)澆板中敷設(shè)電氣線管應(yīng)配合土建施工,不能先設(shè)電氣線管后綁扎鋼筋而造成電氣線管部位鋼筋保護(hù)層及受力截面減小。在管密集處應(yīng)檢查上部鋼筋網(wǎng)設(shè)置,防止板裂縫。梁底部電氣線管敷設(shè)不能破壞梁鋼筋的位置;若有影響,安裝電氣線管應(yīng)避開梁主筋敷設(shè),避免結(jié)構(gòu)受力受到影響。 3 主體施工階段 3.1 一層平口后及時(shí)要求施工單位做安裝樣板間,衛(wèi)生間、廚房檢查排水支管是否與土建窗標(biāo)高矛盾,吊頂后是否影響采光。如有各安裝專業(yè)相互矛盾而影響使用功能的情況,及時(shí)聯(lián)系設(shè)計(jì)處理。 3.2 檢查電氣線管的敷設(shè)對(duì)結(jié)構(gòu)鋼筋位置的影響以及土建施工人員對(duì)安裝管的保護(hù)。 3.3 在墻體施工前,應(yīng)通知安裝單位做好等電位接地,由電氣人員在土建施工時(shí)做好配合,防止遺漏造成返工。 3.4 框梁板鋼筋綁扎完,監(jiān)督施工方電氣均壓環(huán)施工,施工時(shí)糾查電氣施工人員對(duì)鋼筋隨意焊接行為,保證結(jié)構(gòu)受力鋼筋質(zhì)量。 3.5 為配合幕墻的施工,應(yīng)要求電氣施工人員在主體施工時(shí)在接地柱處預(yù)留鋼筋頭,以便幕墻接地施工,避免二次施工對(duì)結(jié)構(gòu)的影響。 3.6 在未隱蔽前檢查燈具線盒設(shè)置位置,位置不正及時(shí)通知調(diào)整。 3.7 監(jiān)督電井、管井、前室、衛(wèi)生間、廚房等管口預(yù)留洞套管的設(shè)置,并在混凝土達(dá)到一定強(qiáng)度不破壞時(shí)起出,加強(qiáng)對(duì)土建混凝土成品保護(hù)。 3.8 開關(guān)、插座的位置各戶偏差控制在5mm之內(nèi)。檢查開關(guān)安裝是否有不便于使用的地方,發(fā)現(xiàn)超偏差及使用不便的,監(jiān)理人員應(yīng)及時(shí)要求調(diào)整,消除觀感缺陷。 3.9 在磚混結(jié)構(gòu)砌體工程中,要求電氣線盒出墻面1.5~2cm,以保證與裝飾面層厚度一致,控制觀感質(zhì)量,做好電氣與土建配合工作。 3.10 檢查消火栓箱、排風(fēng)洞口的平面位置尺寸是否同安裝圖相符,若相互矛盾聯(lián)系設(shè)計(jì)解決。 3.11 應(yīng)防止土建安裝工程變更而設(shè)計(jì)變更未體現(xiàn)安裝土建變更內(nèi)容,應(yīng)考慮變更相互之間的影響,避免出現(xiàn)工程事故。 轉(zhuǎn)貼于 中國(guó)論文下載中
3.12 實(shí)行設(shè)計(jì)變更傳閱制度。土建、安裝人員均進(jìn)行簽閱并抄寫于設(shè)計(jì)圖,寫明日期、來(lái)源、抄件人姓名等,若項(xiàng)目部人員變更能及時(shí)熟知變更內(nèi)容。 4 屋面施工階段 4.1 監(jiān)督土建配合安裝做好雨水口、通氣管、通氣道的留設(shè),做好管口周邊的細(xì)部防水。 4.2 在安裝屋面避雷針、避雷網(wǎng)、航空障礙等工作中,土建應(yīng)配合提供標(biāo)高,保證觀感質(zhì)量。 4.3 土建工程未顯示風(fēng)機(jī)基礎(chǔ)的應(yīng)仔細(xì)地查看安裝圖;屋面水箱間水箱梁與所定設(shè)備基礎(chǔ)圖是否相符。 4.4 屋面電梯機(jī)房電源管線常常因電井封口而缺乏明顯的設(shè)計(jì)標(biāo)注。若有類似現(xiàn)象,在土建施工電梯機(jī)房以前積極聯(lián)系設(shè)計(jì)處理。 5 裝飾、安裝施工階段 5.1 對(duì)安裝各系統(tǒng)立管管口的封堵,要求施工分兩次進(jìn)行填充。首先細(xì)石混凝土摻加防水粉澆筑1/3;等初凝后進(jìn)行第二次澆筑,防止?jié)B水。 5.2 裝飾工程施工前,對(duì)有封堵的電氣線管進(jìn)行疏通,避免裝飾施工墻面、地面后由于電氣線管封堵造成返工。 5.3 監(jiān)督土建施工技術(shù)人員給安裝排水人員提供控制標(biāo)高線,確保地漏的標(biāo)高正確。 5.4 在安裝施工前,要求安裝與土建施工技術(shù)人員對(duì)已確定好的安裝走向、標(biāo)高、坐標(biāo)位置及時(shí)進(jìn)行復(fù)核。 5.5 地面澆筑前要求敷設(shè)給水、采暖管道打壓;帶壓澆筑時(shí)安裝人員要進(jìn)行旁站,發(fā)現(xiàn)泄壓及時(shí)進(jìn)行更換;要求土建施工人員對(duì)敷設(shè)管進(jìn)行覆蓋防護(hù)配合工作。 5.6 安裝衛(wèi)生間器具、管道前,要求施工方對(duì)安裝隊(duì)伍進(jìn)行技術(shù)交底,做好土建墻磚地磚的成品保護(hù)工作。 5.7 土建配合電梯安裝單位,向其提供標(biāo)高及復(fù)核電梯定位放線。避免因電梯定位放線偏差致使電梯門口地面寬窄不一,影響觀感而造成損失。 5.8 土建裝飾進(jìn)行到墻面頂棚涂飾工程,才可安裝電氣設(shè)備,監(jiān)理應(yīng)嚴(yán)把工序;監(jiān)督土建做好開關(guān)、線盒等周邊縫隙的處理,確保觀感質(zhì)量。 5.9 要求土建做好蹲便后管口地板活口設(shè)置,配合安裝工作,便于檢修和更換給水支管。 5.10 衛(wèi)生間、廚房的地面暗敷設(shè)給水、采暖管道時(shí),安裝要配合土建做好對(duì)防水層的保護(hù),土建做好管口及房間四周邊的細(xì)部防水。 5.11 通風(fēng)系統(tǒng)施工前,應(yīng)重視風(fēng)管穿過(guò)樓板、隔墻的坐標(biāo)位置復(fù)核工作。如與土建不一致,及時(shí)糾正圖紙錯(cuò)誤。 5.12 要求吊頂在安裝采暖、熱水等管道施工完保溫層后進(jìn)行。若無(wú)設(shè)計(jì)保溫,應(yīng)及時(shí)建議增加管道保溫,防止冷凝水落至吊頂。 5.13 監(jiān)督做好總包對(duì)各安裝單位的管理及協(xié)調(diào)配合工作(機(jī)械運(yùn)輸、電源、工作面的提供等)以促進(jìn)進(jìn)度。 6 室外管網(wǎng)施工階段 6.1 土建配合安裝確保各系統(tǒng)埋深符合要求,控制好檢查井、化糞池管口標(biāo)高及坡向的正確。 6.2 考慮到檢修因素,建議在室外撿漏溝施工時(shí),應(yīng)設(shè)置檢修井。 6.3 待安裝隊(duì)伍分包的各項(xiàng)工程檢查驗(yàn)收以及,各系統(tǒng)管道全部鋪設(shè)完后,土建施工人員才能進(jìn)行回填,防止返工事件發(fā)生。 6.4 土建配合安裝做好室外消防檢查井、采暖導(dǎo)入口、給水井、排污井、廢水井的設(shè)置,防止因遺漏影響系統(tǒng)運(yùn)行的情況發(fā)生。 7 竣工驗(yàn)收階段 7.1 及時(shí)要求總包單位匯總各安裝分包單位的技術(shù)資料。 7.2 組織各專業(yè)單項(xiàng)驗(yàn)收(電梯、消防、人防、變配電室),土建配合整改,給工程竣工驗(yàn)收提供前提條件。 7.3 監(jiān)理部門組織好預(yù)驗(yàn),土建安裝相互配合完善整改,做到成品保護(hù),工完場(chǎng)清。安裝與土建配合施工是一項(xiàng)復(fù)雜的工作,以上所述只是我個(gè)人在工作中的一點(diǎn)體會(huì)。加強(qiáng)土建與安裝在施工中的協(xié)調(diào)配合,將有力地保證工程整體質(zhì)量及安全使用功能,也是施工方降低成本的有效措施。監(jiān)理部門應(yīng)加強(qiáng)在這項(xiàng)工作中的監(jiān)督管理,使工程管理水平進(jìn)一步提高,確保監(jiān)理工程質(zhì)量
關(guān)鍵詞 PBL模式;地方高校;給排水科學(xué)與工程
中圖分類號(hào):G642.4 文獻(xiàn)標(biāo)識(shí)碼:B
文章編號(hào):1671-489X(2015)16-0122-03
1 前言
廣東工業(yè)大學(xué)是一所地方重點(diǎn)高校,是廣東省最早成立給排水工程本科專業(yè)的學(xué)校。廣東作為經(jīng)濟(jì)大省,國(guó)民生產(chǎn)總值等經(jīng)濟(jì)指標(biāo)在國(guó)內(nèi)一直名列前茅。各大建設(shè)公司、各類設(shè)計(jì)院、材料設(shè)備生產(chǎn)企業(yè)、水務(wù)集團(tuán)等單位規(guī)模在不斷擴(kuò)大,效益很好,對(duì)人才的需求相當(dāng)旺盛。給排水專業(yè)畢業(yè)生的就業(yè)前景很樂觀,每屆畢業(yè)生就業(yè)率達(dá)100%。目前,95%的畢業(yè)生已經(jīng)分布在各個(gè)大中小企事業(yè)單位,并發(fā)揮著骨干人才的作用。但美中不足的是,部分畢業(yè)生剛剛踏入社會(huì)時(shí),動(dòng)手能力、應(yīng)用創(chuàng)新能力與團(tuán)隊(duì)合作能力仍然不能滿足企業(yè)對(duì)人才能力的要求。
隨著各個(gè)院校對(duì)人才培養(yǎng)模式的優(yōu)化,以及與企業(yè)進(jìn)行產(chǎn)、學(xué)、研合作的深入,高校是否具有長(zhǎng)遠(yuǎn)的目光,采用先進(jìn)的教學(xué)模式與人才培養(yǎng)方案,使培養(yǎng)的學(xué)生能更適應(yīng)用人單位與社會(huì)的需求,對(duì)畢業(yè)生在社會(huì)各個(gè)相關(guān)領(lǐng)域是否受歡迎起到?jīng)Q定性的作用。阿爾堡大學(xué)PBL(Problem Based Learning,基于問題式教學(xué))模式在不同國(guó)家不國(guó)高校的成功應(yīng)用提供了新的人才培養(yǎng)思路[1-6]。
2 PBL模式對(duì)地方高校給排水科學(xué)與工程專業(yè)人才培養(yǎng)的啟發(fā)
阿爾堡大學(xué)PBL模式的特點(diǎn) PBL人才培養(yǎng)模式,是一種圍繞精心設(shè)計(jì)與實(shí)際一致的問題情境來(lái)組織課程與教學(xué)的教育方式。學(xué)習(xí)者在認(rèn)知教練的引導(dǎo)下,通過(guò)判斷問題、歸納假設(shè)、推斷研究數(shù)據(jù)、試驗(yàn)行動(dòng)、總結(jié)問題解決的策略,直至最后得出解決問題的最佳方法,來(lái)發(fā)展自身的批判性思維,提高解決問題的能力和協(xié)作的技能等。PBL人才培養(yǎng)模式是一種教學(xué)策略或教學(xué)方式,它強(qiáng)調(diào)把學(xué)習(xí)設(shè)置到相關(guān)背景的、有意義的問題情境中。通過(guò)讓學(xué)習(xí)者組織團(tuán)隊(duì)、合作解決實(shí)際生活中的問題,來(lái)學(xué)習(xí)隱含于問題背后的科學(xué)知識(shí),促進(jìn)學(xué)習(xí)者形成批判性思維,獲得自主學(xué)習(xí)與協(xié)作學(xué)習(xí)的技能以及高效解決問題的能力。
PBL人才培養(yǎng)模式實(shí)踐表明,在傳統(tǒng)教學(xué)思想中,教師“知識(shí)的傳授者”的角色已經(jīng)不適應(yīng)新時(shí)代探索性學(xué)習(xí)的要求。PBL教學(xué)法是一種嶄新的教育理念,對(duì)帶教教師提出更高的要求。與傳統(tǒng)的教學(xué)方法相比,帶教教師的作用不再是“我講你聽,我動(dòng)手你觀摩”,而是放手讓學(xué)生去親自實(shí)踐。為使學(xué)生了解實(shí)際工作中如何解決隨時(shí)遇到的問題,激發(fā)學(xué)生對(duì)這門學(xué)科產(chǎn)生興趣的重任,達(dá)到授之以漁的目的,帶教教師就要積極轉(zhuǎn)變角色,適應(yīng)PBL教學(xué)法對(duì)教師的要求。
PBL模式下地方高校給排水科學(xué)與工程人才培養(yǎng)應(yīng)具備的特色 結(jié)合阿爾堡大學(xué)PBL人才培養(yǎng)模式特點(diǎn)與廣東經(jīng)濟(jì)發(fā)展特點(diǎn),對(duì)給排水科學(xué)與工程本科專業(yè),應(yīng)該重點(diǎn)培養(yǎng)學(xué)生的實(shí)際操作能力。尤其是加強(qiáng)城市水質(zhì)與水務(wù)工程、建筑水科學(xué)與消防工程等各專業(yè)方向在工藝設(shè)計(jì)、施工技術(shù)、運(yùn)營(yíng)管理及技術(shù)咨詢服務(wù)等相關(guān)基礎(chǔ)知識(shí)和專業(yè)技能的培養(yǎng),增加專業(yè)技能訓(xùn)練和實(shí)習(xí),增加專業(yè)課程設(shè)計(jì)工作量與深度,有針對(duì)性地建立一批產(chǎn)學(xué)研實(shí)習(xí)基地,如各類設(shè)計(jì)研究院、凈水廠、設(shè)備及管材生產(chǎn)廠家、建筑安裝集團(tuán)、技術(shù)咨詢公司等,使師生與社會(huì)零距離接觸,實(shí)踐教學(xué)活動(dòng)更系統(tǒng)、更深入、更具體、更實(shí)用。這樣培養(yǎng)的學(xué)生適應(yīng)了人才市場(chǎng)需求,提高了畢業(yè)生就業(yè)競(jìng)爭(zhēng)力,也形成地方高校給排水科學(xué)與工程專業(yè)自己的培養(yǎng)特色。
目前,中國(guó)很多大學(xué)已經(jīng)引入PBL教學(xué)理念,但大多是醫(yī)科院校。隨著社會(huì)經(jīng)濟(jì)的發(fā)展和全球化趨勢(shì)的增強(qiáng),大學(xué)教育越來(lái)越強(qiáng)調(diào)在加強(qiáng)產(chǎn)、學(xué)、研聯(lián)合的同時(shí),增加學(xué)生的主動(dòng)性和操作能力。阿爾堡大學(xué)PBL教學(xué)模式在各學(xué)科教學(xué)中的運(yùn)用,對(duì)地方高校給排水科學(xué)與工程教學(xué)改革有一定的啟示。地方高校適宜根據(jù)地方經(jīng)濟(jì)發(fā)展特色、專業(yè)的實(shí)際情況,以實(shí)際問題為導(dǎo)向,以團(tuán)隊(duì)為基礎(chǔ)展開教學(xué),促進(jìn)教學(xué)、科研和實(shí)際的互動(dòng),提高學(xué)生解決問題的能力。
PBL模式宜與傳統(tǒng)教學(xué)方法相結(jié)合 誠(chéng)然,學(xué)習(xí)阿爾堡PBL人才培養(yǎng)模式時(shí),應(yīng)結(jié)合地方高校的實(shí)際情況進(jìn)行吸收與消化。廣東工業(yè)大學(xué)是省屬重點(diǎn)高校,在校生規(guī)模很大,如果完全遵循阿爾堡PBL人才培養(yǎng)模式是不現(xiàn)實(shí)的,學(xué)習(xí)PBL人才培養(yǎng)模式的理念很重要。針對(duì)地方高校給排水科學(xué)與工程專業(yè)的特點(diǎn),適宜走PBL模式和傳統(tǒng)教學(xué)方法相結(jié)合的道路。在傳統(tǒng)教學(xué)方法的基礎(chǔ)上,使學(xué)生掌握了一定的基礎(chǔ)知識(shí)后,通過(guò)選擇適當(dāng)?shù)墓こ虒?shí)例,圍繞實(shí)例實(shí)行PBL的教學(xué)方法,讓學(xué)生早期接觸城市水科學(xué)與建筑水科學(xué)中可能存在的熱點(diǎn)與難點(diǎn)問題,把基礎(chǔ)知識(shí)與專業(yè)知識(shí)結(jié)合起來(lái),以期達(dá)到既系統(tǒng)地教育學(xué)生專業(yè)理論知識(shí),又通過(guò)PBL模式培養(yǎng)學(xué)生解決實(shí)際問題的能力,以及提高學(xué)生自主地涉獵專業(yè)科技前沿知識(shí)、拓展專業(yè)相關(guān)知識(shí)領(lǐng)域的能力。
3 PBL模式在給排水科學(xué)與工程專業(yè)應(yīng)用中的思考
進(jìn)行課程體系的改革 如果要保障學(xué)習(xí)效率與效果,因?yàn)閹熧Y力量有限,小組不能太多,每組人數(shù)也不能太多。廣東工業(yè)大學(xué)需要根據(jù)自己的特點(diǎn)利用PBL模式,對(duì)課程體系進(jìn)行科學(xué)設(shè)置與規(guī)劃。比如課程設(shè)置可以分為多個(gè)層次(基礎(chǔ)課、專業(yè)課、專業(yè)技能課程與創(chuàng)新科技實(shí)踐),以滿足不同學(xué)生學(xué)習(xí)的要求。對(duì)學(xué)有余力的學(xué)生,可以設(shè)置綜合性的、具有創(chuàng)新性的實(shí)驗(yàn)實(shí)訓(xùn)項(xiàng)目,甚至可以跟著教師、博士生、研究生做課題。教師可以分一個(gè)局部的工作給本科生做,這種深入的學(xué)習(xí),學(xué)校也給定學(xué)分,并適當(dāng)給予獎(jiǎng)勵(lì)。這種做法有點(diǎn)類似科技制作,充分發(fā)揮學(xué)有余力學(xué)生的創(chuàng)新思維。
同時(shí),PBL模式的教學(xué)體系,課程不宜多,可以將某些課程合并,課時(shí)適當(dāng)增加,主要是增加實(shí)踐環(huán)節(jié)學(xué)時(shí),也即PBL模式的項(xiàng)目設(shè)計(jì);建議理論學(xué)時(shí)與實(shí)踐環(huán)節(jié)學(xué)時(shí)按1:1分配;建議在大學(xué)一年級(jí)就設(shè)置相應(yīng)的專業(yè)課,而不僅僅是基礎(chǔ)課程的學(xué)習(xí)。增加基礎(chǔ)課程與專業(yè)課程的緊密聯(lián)系與結(jié)合,基礎(chǔ)課程學(xué)時(shí)應(yīng)減少。PBL模式主要是針對(duì)項(xiàng)目所要使用的知識(shí)進(jìn)行授課,基礎(chǔ)課程教師與專業(yè)課程教師應(yīng)充分交流,如何找到兩者的切入點(diǎn)而設(shè)置合適的項(xiàng)目很關(guān)鍵。
根據(jù)專業(yè)理論知識(shí),合理、科學(xué)地設(shè)計(jì)項(xiàng)目與項(xiàng)目中的問題 廣東工業(yè)大學(xué)給排水科學(xué)與工程專業(yè),前期有部分教學(xué)環(huán)節(jié)開始運(yùn)用基于PBL的先進(jìn)教學(xué)模式,但主要問題是,教師仍然采用提前將準(zhǔn)備工作做得比較充分,學(xué)生只需要沿著教師的思路進(jìn)行研究的方式,不能極大地發(fā)揮學(xué)生的主觀能動(dòng)性。因此,根據(jù)專業(yè)理論知識(shí),如何合理、科學(xué)地設(shè)計(jì)項(xiàng)目以及項(xiàng)目中的問題,進(jìn)一步增強(qiáng)教師與學(xué)生的互動(dòng),激發(fā)學(xué)生利用網(wǎng)絡(luò)資源、圖書館資源等,對(duì)運(yùn)用PBL模式于教學(xué)中顯得很重要。
在本專業(yè)中,基于PBL教學(xué)模式理念,建議利用課程論文的形式,給定一個(gè)具有時(shí)局性的問題,要求學(xué)生查閱資料、整理論文到最后演講,老師與同學(xué)一起提問;課程設(shè)計(jì)的任務(wù)不同,每個(gè)學(xué)生需要自己做;尤其是實(shí)驗(yàn)實(shí)訓(xùn)課,只給定原始條件,不給定操作條件與將達(dá)到的目的和效果,不同學(xué)生可以選用不同的條件進(jìn)行實(shí)踐,得出不同結(jié)論,選出最佳狀況,寫總結(jié)報(bào)告;實(shí)驗(yàn)不要太多,但要具有綜合性。不限制一次做完一個(gè)系列的實(shí)驗(yàn),同一個(gè)系列的實(shí)驗(yàn)可以多次完成,每次可能出現(xiàn)不同的結(jié)果。在進(jìn)行實(shí)驗(yàn)結(jié)果評(píng)估時(shí),以體現(xiàn)自主性、靈活性與一定的創(chuàng)新性為主要評(píng)估目標(biāo)。
爭(zhēng)取更多的PBL模式主導(dǎo)人員 廣東工業(yè)大學(xué)給排水科學(xué)與工程在校生規(guī)模大,每年招收100學(xué)生,但在職教師才12人。因此,爭(zhēng)取更多的PBL模式主導(dǎo)人員很重要。研究生或博士生可以發(fā)展成為教師的助手,共同對(duì)本科生對(duì)設(shè)計(jì)的問題進(jìn)行指導(dǎo)、監(jiān)督與跟蹤,開通專業(yè)知識(shí)論壇、舉辦專業(yè)問題討論會(huì)等。另外,對(duì)實(shí)驗(yàn)室教師和實(shí)訓(xùn)課教師進(jìn)行PBL人才培養(yǎng)模式理念的培訓(xùn),讓他們也參與到PBL教學(xué)方法中來(lái)。
學(xué)校應(yīng)該從PBL新模式的角度進(jìn)一步重視教師隊(duì)伍的建設(shè),并加大配套設(shè)施與教學(xué)條件的建設(shè) PBL教學(xué)方法對(duì)教師的素質(zhì)有較高的要求,需要一支高素質(zhì)的教師隊(duì)伍,適應(yīng)新的教育思想并具有新的知識(shí)結(jié)構(gòu),還應(yīng)掌握討論氣氛的調(diào)動(dòng)、引導(dǎo)等技巧。而造就這樣的教師隊(duì)伍并非易事,教師要切實(shí)從傳統(tǒng)的教學(xué)角色中抽離出來(lái),適應(yīng)新的教學(xué)模式,才能更好地推進(jìn)PBL教學(xué)法的實(shí)施。另外,培養(yǎng)學(xué)生的思考能力、動(dòng)手能力、創(chuàng)新能力,需要較多的配套設(shè)施與教學(xué)條件。
4 結(jié)論
阿爾堡大學(xué)PBL人才培養(yǎng)模式在國(guó)際上影響很大,其模式在不同學(xué)科中的運(yùn)用也產(chǎn)生了明顯的效果。但是,由于各個(gè)學(xué)科的性質(zhì)不同,決定了該模式在教學(xué)中將運(yùn)用不同的教育原理。因此,模式在不同學(xué)科或?qū)I(yè)教育運(yùn)用中的具體形式既有共性,又存在一定的差異性,比如教學(xué)主題的定義、項(xiàng)目作業(yè)的選擇、問題的定義、課程和項(xiàng)目作業(yè)的聯(lián)系形式、導(dǎo)師職責(zé)以及學(xué)生小組規(guī)模等。將PBL模式與地方高校人才培養(yǎng)理念與教學(xué)理念相結(jié)合,根據(jù)地方高校給排水科學(xué)與工程專業(yè)的特點(diǎn),有目的地、合理地吸收該模式的精髓,有效地將該理念應(yīng)用到專業(yè)教學(xué)中,促使本科生形成批判性思維,獲得自主學(xué)習(xí)與協(xié)作學(xué)習(xí)的技能以及高效解決問題的能力,更好地適應(yīng)社會(huì),需要對(duì)給排水科學(xué)與工程專業(yè)現(xiàn)有人才培養(yǎng)方案進(jìn)行合理的設(shè)計(jì),才能達(dá)到預(yù)期的目標(biāo)。
參考文獻(xiàn)
[1]余世金,潘少兵,操ZZ.談PBL模式教學(xué)中生態(tài)學(xué)主題選擇與問題設(shè)計(jì)[J].教育教學(xué)論壇,2015(2):281-282.
[2]崔瑩.基于PBL的旅游管理專業(yè)實(shí)踐教學(xué)模塊構(gòu)建[J].現(xiàn)代教育科學(xué):高教研究,2014(5):129-132.
[3]何毛毛,張曉薇,孫紅.PBL教學(xué)方法在婦產(chǎn)科教學(xué)中的應(yīng)用[J].中國(guó)高等醫(yī)學(xué)教育,2014(9):93-94.
[4]殷麗天,楊小榮,趙欣,等.構(gòu)建基于生理學(xué)特點(diǎn)的多元化PBL教學(xué)模式[J].中國(guó)高等醫(yī)學(xué)教育,2014(8):114-115.